journal article·2020-02

Activated charcoal cooled to liquid helium temperature exhibiting pumping for hydrogen and helium gases

R. Gangradey, V.L. Tanna, S. Mukherjee, J. Mishra, P. Nayak, P. Panchal

Vacuum· Volume 172
Publisher page

Abstract

Abstract Cryopump is a widely studied subject, but an attempt towards improvement can be appreciated. In this paper, the sorbent used is coconut shell charcoal. It is microporous with pore size in the range of 2–50 nm and pore surface area of 1285 (±5%) m2/gm. To the metal surface, the charcoal coating is done using a glue. It was developed involving industry participation. The glue is thermally conducting. It is stable during thermal cycling from 4 K to 200 °C and is vacuum compatible with a low outgassing rate. The charcoal coated sample panels were tested for thermal cycling from 4 K to 200 °C. Charcoal, and glue was then used to coat cryopanel of 0.1 m2. The paper discusses the results of pumping speed by mounting the cryopanel cooled to liquid Helium temperature to pump gases like Hydrogen and Helium in an experimental set. Pumping speed found for Hydrogen and Helium gases is in the range of 2500 and 2800 l/s, respectively. Molflow code based on the Monte Carlo technique developed by CERN was used to simulate the experimental setup. This paper also discusses Molflow simulation results.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Spacecraft and Cryogenic Technologies · Superconducting Materials and Applications · Geothermal Energy Systems and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Roth · 1990
2. Haefer · 1989
3. The production of vacuum: past, present and future10.1016/0042-207X(79)90162-3 ↗
4. Day · 2007
5. The vacuum systems of ITER10.1016/j.vacuum.2008.05.010 ↗
6. Characterization of charcoals for Helium cryopumping in fusion devices10.1116/1.574424 ↗
7. Evaluation of charcoal sorbents for Helium cryopumping in fusion reactors10.1116/1.574141 ↗
8. Adsorption characteristic study of activated carbons down to 4.5 k, Mater
9. OGMS: a facility to measure out-gassing rate of materials10.1016/j.mspro.2014.07.034 ↗
10. Flash method of determining thermal diffusivity, heat capacity, and thermal conductivity10.1063/1.1728417 ↗
11. Thermal diffusivity measurement of G-10 material at low temperatures using xenon flash method
12. Devices · 2011
13. American Society for Testing and Materials (ASTM) C 1371 – 98, Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers, C 1371-9, 1999.
14. Emissivity of silver and stainless steel from 80K to 300K: application to ITER thermal shields10.1016/j.cryogenics.2014.01.002 ↗
15. Low temperature radiative properties of materials used in cryogenics10.1016/j.cryogenics.2004.11.010 ↗
16. Component tests on fast heating and cooling with cryopanels for use in the ITER primary vacuum system10.1016/S0920-3796(98)00154-9 ↗
17. Recommended procedure for measuring pumping speeds10.1116/1.574420 ↗
18. Recommended practices for measuring the performance and characteristics of closed-loop gaseous Helium cryopumps10.1116/1.582023 ↗
19. Barron · 1999
20. Introduction to MOLFLOW+: new graphical processing unit-based Monte Carlo code for simulating molecular flows and for calculating angular coefficients in the compute unified device architecture environment10.1116/1.3153280 ↗