Design, fabrication and characterization of a windowless extrapolation chamber for low-energy X-rays: Experimental and Monte Carlo results
Source abstract
Abstract
Abstract Extrapolation chamber is a special parallel-plate ionization chamber, particularly suggested for low penetrating radiations. Its sensitive volume is varied through a change of the inter-electrode distance, ideally satisfying the Bragg-Gray cavity theory. A windowless extrapolation chamber was designed and constructed for low-energy X-rays, produced at the tube voltage of 70–100 kV. It consists of the following elements and innovation. The electrodes of the chamber are made of a homogenous block of graphite instead of a coating graphite layer to reduce the leakage current. Also, the entrance window (first layer of front window) has been eliminated to decrease the beam perturbation. To the best of our knowledge, this type of chamber has not been used in low energy X-rays before. The performance of the chamber was investigated in terms of its saturation curve, polarity effect, leakage current, linearity of response and short-term stability. It was also simulated using Monte Carlo method and in the worst case, the relative ionization current obtained in experiment differs about 4.5% with that in the simulation result. Moreover, the influence of chamber components on its response was examined. All of the results showed the feasibility of its use for detection of 70–100 kV X-rays.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Radiotherapy Techniques · Medical Imaging Techniques and Applications · Radiation Detection and Scintillator Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Performance of a prototype of an extrapolation minichamber in various radiation beams10.1016/j.apradiso.2007.03.021 ↗
2. Instruments for radiation detection10.1007/978-3-642-18549-6_12 ↗
3. Böhm · 1986
4. Surface dose measurements with commonly used detectors: a consistent thickness correction method10.1120/jacmp.v16i5.5572 ↗
5. Variance reduction technique in a beta radiation beam using an extrapolation chamber10.1016/j.apradiso.2017.06.017 ↗
6. The measurement of tissue dose in terms of the same unit for all ionizing radiations10.1148/29.2.202 ↗
7. Characteristics of an extrapolation chamber FWT type EIC.1 in beta radiation fields
8. Dosimetry of planar and punctiform beta sources using an automated extrapolation chamber and radiochromic dye films10.1093/oxfordjournals.rpd.a081117 ↗
9. Results on 90Sr+90Y applicators dosimetry using extrapolation chambers
10. A special mini-extrapolation chamber for calibration of 90Sr+90Y sources10.1088/0031-9155/50/12/013 ↗
11. Characterization of an extrapolation chamber as a primary standard dosimeter for beta radiation
12. Böhm extrapolation chamber: study of its behavior in beta radiation fields at the Calibration Laboratory of IPEN10.1016/j.radphyschem.2014.04.035 ↗
13. Calibration of the 90Sr+90Y ophthalmic and dermatological applicators with an extrapolation ionization minichamber10.1016/j.apradiso.2013.10.022 ↗
14. A prototype of an extrapolation chamber for beta radiation beams of 90Sr+90Y10.1007/s10967-014-3117-y ↗
15. Characteristics of an extrapolation chamber for ß-ray protection level measurements10.1063/1.370782 ↗
16. Extrapolation chamber response in low-energy x radiation standard beams10.1063/1.1332416 ↗
17. Characterization of an extrapolation chamber for low-energy X-rays: experimental and Monte Carlo preliminary results10.1016/j.apradiso.2011.12.012 ↗
18. Application of extrapolation chambers in low-energy X-rays as reference systems10.1016/j.apradiso.2012.03.038 ↗
19. Determination of true null electrode spacing of an extrapolation chamber for x-ray dosimetry10.1088/1742-6596/733/1/012093 ↗
20. Extrapolation ionization chamber dosimetry of fluorescent X-ray energies from 4.5 to 19.6 keV10.1667/RR14384.1 ↗
21. Windowless extrapolation chamber measurement of surface dose rate from a 90Sr/90Y ophthalmic applicator10.1016/j.radmeas.2017.11.003 ↗
22. Monte Carlo simulation applied to the characterization of an extrapolation chamber for beta radiation dosimetry10.1016/j.radphyschem.2015.01.010 ↗
23. Monte Carlo modeling of the response of NRC's primary beta standard10.1118/1.1997347 ↗
24. Improvement in the energy characteristics of a vacuum ionization chamber
25. Coordinate-sensitive ionization chamber with high spatial resolution10.1016/j.nima.2005.01.256 ↗
26. High vacuum ionization chamber with high spatial resolution for monitoring synchrotron radiation beams10.1134/S1027451011110085 ↗
27. Determination of correction factors in beta radiation beams using Monte Carlo method10.1016/j.apradiso.2018.06.011 ↗
28. International Electrotechnical Commission · 2005
29. International Electrotechnical Commission · 2011
30. Saturation corrections for plane-parallel ionisation chambers10.1088/0031-9155/21/5/004 ↗
31. Saturation curves of parallel‐plate ionization chambers10.1118/1.595292 ↗
32. Absorbed dose determination in external beam radiotherapy: an international code of practice for dosimetry based on standards of absorbed dose to water
33. Evaluation of a plane-parallel ionization chamber for low-energy radiotherapy beams
34. Prescribing, recording and reporting photon beam therapy
35. Establishment of a calibration curve for an isocentric cobalt unit using Monte Carlo simulation10.1007/s41365-017-0275-y ↗