Assessment of mechanical and corrosion properties of plasma oxidized medical grade NiTi wire
Source abstract
Abstract
Abstract Nitinol is an excellent biomaterial amongst smart materials, which have shape and form memory effects and superelasticity, and is mainly used as orthodontic wire and coronary stent. One of the associated drawbacks, however, is nickel release into bloodstream, which can achieve critical levels. In this work, F2063 Nitinol wire was plasma-oxidized in order to obtain a TiO2 protective layer ranging from 50 to 80 nm, which helps blocking nickel release and enhances corrosion properties, thus avoiding or decreasing foreign body reactions. Two power sources (DC and RF) were evaluated and the resulting surfaces from plasma treated samples were characterized. According to the obtained results, tensile tests showed a slight improvement in superlastic elongation and in vitro corrosion resistance in specimens treated by plasma. The findings also suggest that RF power source is best suited to achieve a desired nano-scale layer in NiTi alloys. In this new light, plasma-assisted treatments can be performed in memory-shape alloys, aiming the obtention of a well adhered, corrosion improving and mechanical properties enhancing coating.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Shape Memory Alloy Transformations · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Nitinol manufacturing and micromachining: a review of processes and their suitability in processing medical-grade nitinol10.1016/j.jmapro.2019.01.003 ↗
2. Austenite-martensite phase transformation of biomedical Nitinol by ball burnishing10.1016/j.jmatprotec.2014.07.019 ↗
3. Nitinol stent design - understanding axial buckling10.1016/j.jmbbm.2014.08.029 ↗
4. Impact of nitinol stent surface processing on in-vivo nickel release and biological response10.1016/j.actbio.2018.03.036 ↗
5. A. Bhardwaj, A.K. Gupta, S.K. Padisala, K. Poluri, SC, (2019).
6. A new route to biocompatible Nitinol based on a rapid treatment with H 2/O 2 gaseous plasma10.1016/j.apsusc.2018.12.140 ↗
7. Evaluation of nickel ion release from various orthodontic arch wires: an in vitro study10.4103/2231-0762.130921 ↗
8. A comparative study of surface characterization and corrosion performance properties of laser surface modified biomedical grade nitinol10.1016/j.apsusc.2018.11.045 ↗
9. Study OF nickel ION release IN simulated body fluid from C + -implanted nickel titanium alloy10.1142/S0218625X16500451 ↗
10. Nitinol surfaces for implantation10.1007/s11665-009-9498-3 ↗
11. NiTi coated with oxide and polymer films in the in vivo healing processes10.1016/j.jmrt.2018.06.015 ↗
12. Corrosion resistance of NiTi shape memory alloy after hybrid surface treatment using low-temperature plasma10.1016/j.vacuum.2016.12.034 ↗
13. Optimization of electropolishing on NiTi alloy stents and its influence on corrosion behavior
14. In situ observation of surface oxide layers on medical grade Ni-Ti alloy during straining10.1002/jbm.a.31946 ↗
15. Critical overview of Nitinol surfaces and their modifications for medical applications10.1016/j.actbio.2008.01.013 ↗
16. Corrosion resistance, surface mechanical properties, and cytocompatibility of plasma immersion ion implantation-treated nickel-titanium shape memory alloys10.1002/jbm.a.30413 ↗
17. The use of hollow cathodes in deposition processes: a critical review10.1016/j.tsf.2015.02.066 ↗
18. Characterisation of surface-modified nickel titanium alloys10.1016/S0921-5093(02)00818-3 ↗
19. Standard specification for wrought nickel-titanium shape memory alloys for medical devices and surgical implants
20. Plasma surface modification of NiTi shape memory alloy10.1016/j.surfcoat.2006.02.022 ↗
21. Hoffman · 1998
22. Functionality OF bare nitinol surfaces10.1142/S1793604709000582 ↗
23. ASTM Int · 2016
24. Standard test method for conducting cyclic potentiodynamic polarization measurements to determine the corrosion susceptibility of small implant
25. Kay · 2010
26. Development of biomimetic NiTi alloy: influence of thermo-chemical treatment on the physical, mechanical and biological behavior10.3390/ma9060402 ↗
27. Reduction of Ni release and improvement of the friction behaviour of NiTi orthodontic archwires by oxidation treatments10.1007/s10856-011-4292-9 ↗
28. Effects of oxide layer composition and radial compression on nickel release in nitinol stents10.1007/s40830-015-0028-x ↗
29. Structure and properties of nitrided surface layer produced on NiTi shape memory alloy by low temperature plasma nitriding10.1016/j.apsusc.2014.07.109 ↗
30. Oxidation and diffusion processes in nickel-titanium oxide systems10.1016/0039-6028(93)90287-T ↗
31. Similarities and differences between direct current and radio-frequency glow discharges: a mathematical simulation10.1039/b000519n ↗
32. Powell · 1999
33. Solid, shape recovered “bulk” Nitinol: Part I-Tension-compression asymmetry10.1016/j.msea.2011.03.060 ↗
34. Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in Ringer's solution10.1002/(SICI)1097-4636(199612)32:4<583::AID-JBM11>3.0.CO;2-F ↗
35. Electrophoretic deposition of graphene oxide on NiTi alloy for corrosion prevention10.1016/j.vacuum.2018.12.032 ↗
36. Influence of low temperature plasma oxynitriding on the mechanical behavior of NiTi shape memory alloys10.1016/j.vacuum.2018.07.027 ↗
37. Structure and properties of TiC/Ti coatings fabricated on NiTi by plasma immersion ion implantation and deposition10.1016/j.vacuum.2012.05.023 ↗