Thermal transpiration of helium and nitrogen in 50-μm bore silica capillaries
Source abstract
Abstract
Abstract Thermal transpiration of helium and nitrogen in silica 50-μm capillaries between temperatures of 340 and 300 K has been measured in the pressure range of 100 Pa –to 10 kPa by the differential method using apparatus in which the gases are back-filled into a clean UHV-compatible system. For helium at 100 Pa the magnitude of the effect is close to that predicted by kinetic theory. Calculations based on the semi-empirical formula of Takaishi and Sensui are in good agreement with the helium data over the whole pressure range but not for nitrogen below 1 kPa. Estimates of the thermomolecular pumping speeds per capillary have been made.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Spacecraft and Cryogenic Technologies · Gas Dynamics and Kinetic Theory · High-pressure geophysics and materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (13)
Show source-provided references
1. Reynolds · Philos Trans Roy Soc London · 1879 · 727
2. Poulter · Vacuum · 1933 · 1983 · 311
3. Young · J Vac Sci Technol B · 1917 · 1999 · 280
4. York · Vacuum · 1955 · 1999 · 133
5. Takaishi · Trans Faraday Soc · 1959 · 1963 · 2503
6. Jitschin · J Vac Sci Technol A · 1987 · 372
7. Kennard EH. Kinetic theory of gases. New York: McGraw-Hill,1938. p. 66.
8. Edmonds · J Vac Sci Technol · 1965 · 182
9. Hobson · J Vac Sci Tech · 1970 · 351
10. Liang · J Phys Chem · 1957 · 1953 · 910
11. Dayton BB. In: Lafferty JM, editor. Foundations of vacuum science and technology. New York:Wiley, 1998 (chapter 1).
12. Knudsen M. Kinetic theory of gases. 2nd ed. London: Methuen, 1946. p. 33.
13. Sharipov · J Vac Sci Technol A · 1915 · 1997 · 2434