Numerical simulation of point-to-plane corona discharge using a Monte Carlo method
Source abstract
Abstract
Abstract Monte Carlo simulation techniques are used to study the dynamical properties of charged particles in point-to-plane corona discharge. The numerical model includes the release of electron–ion pairs by photoionization and secondary electron emission from cathode as well as the first Townsend ionization. The simulation results of negative corona discharge in nitrogen show that electron avalanche takes place in the region of high electric field near pin electrode and the photoionization is the essential mechanism to sustain the discharge as well as electron impact ionization.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Plasma Diagnostics and Applications · Plasma Applications and Diagnostics · Electrohydrodynamics and Fluid Dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (7)
Show source-provided references
1. Chang · IEEE Trans Plasma Sci · 1991 · 19 · 115210.1109/27.125038 ↗
2. Kline · Phys Rev A · 1972 · 5 · 79410.1103/PhysRevA.5.794 ↗
3. Davies · Proc IEEE · 1972 · 118 · 816
4. Koh · J Appl Phys · 1993 · 73 · 420510.1063/1.352825 ↗
5. Brown · 1967
6. Penney · J Appl Phys · 1970 · 41 · 57210.1063/1.1658715 ↗
7. Lamma · J Appl Phys · 1974 · 45 · 10310.1063/1.1662943 ↗