Ionization efficiency calculations for cavity thermoionization ion source
Source abstract
Abstract
The numerical model of a thermoemission ion source was used for source ionization efficiency calculations. The dependency of ionization efficiency on working parameters like ionizer length and extraction voltage was discussed, and a good agreement with theoretical predictions was achieved. It was shown that increasing the ionizer length does not significantly change the obtained ionization efficiency. Extraction voltages up to a few thousand of volts are sufficient to obtain reasonable efficiency. © 2008 Elsevier Ltd. All rights reserved.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · Heat Transfer and Boiling Studies · Mass Spectrometry Techniques and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (9)
Show source-provided references
1. Beyer · Nucl Instrum Methods · 1971 · 96 · 34710.1016/0029-554X(71)90613-6 ↗
2. Kirchner · Nucl Instrum Methods A · 1990 · 292 · 20310.1016/0168-9002(90)90377-I ↗
3. Latuszyński · Nucl Instrum Methods · 1974 · 120 · 32110.1016/0029-554X(74)90053-6 ↗
4. Latuszyński · Nucl Instrum Methods · 1975 · 125 · 6110.1016/0029-554X(75)90553-4 ↗
5. Saha · Philos Mag · 1920 · 40 · 47210.1080/14786441008636148 ↗
6. Langumir · Phys Rev · 1923 · 21 · 380
7. Latuszyński · Vacuum · 2007 · 81 · 115010.1016/j.vacuum.2007.01.006 ↗
8. Hockney · 1987
9. Press · 1986