journal article·2015-01

Optimum design for the carbon nanotube based micro-focus X-ray tube

Hyun Suk Kim, Edward Joseph D. Castro, Choong Hun Lee

Vacuum· Volume 111
Publisher page

Abstract

Abstract The current work reports the optimum design conditions of a direct current plasma enhanced chemical vapor deposition grown multi-walled carbon nanotube based micro-focus X-ray tube with dual focusing lens. Extensive simulations were performed in order to determine the configuration that would generate a desirable focal spot size. Several dimensions of the X-ray basic structure and the focusing lens were manipulated using a commercially available simulation package. A manipulation of the factors (i.e. geometric parameter, axial distances, and bias voltages variances) and their effects on the focal spot size were also analyzed. A remarkable reduction in the focal spot size was achieved at the anode target via simulation and high resolution images were obtained in a prototype X-ray generator through standard line pattern test.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Electron Microscopy Techniques and Applications · Advanced X-ray Imaging Techniques · Carbon Nanotubes in Composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. Paulus · Neoplasia · 2000 · 2 · 6210.1038/sj.neo.7900069 ↗
2. Bartling · Curr Med Imag Rev · 2007 · 3 · 4510.2174/157340507779940327 ↗
3. Bushberg · 2002
4. Suetens · 2009
5. Heo · Appl Phys Lett · 2007 · 90 · 18310910.1063/1.2735549 ↗
6. Davis · Physiol Meas · 1996 · 17 · 12110.1088/0967-3334/17/3/001 ↗
7. Chun · Phys Med Biol · 2004 · 49 · 388910.1088/0031-9155/49/17/005 ↗
8. Guy · 2005
9. Kawakita · J Vac Sci Technol B · 2006 · 24 · 95010.1116/1.2183785 ↗
10. Riddle · J Vac Sci Technol · 1978 · 15 · 857
11. Sultana · Proc SPIE · 2010 · 7622 · 76225G10.1117/12.844350 ↗
12. Liu · Rev Sci Instrum · 2006 · 77 · 05430210.1063/1.2198793 ↗
13. Yabushita · J Vac Sci Technol B · 2008 · 26 · 70210.1116/1.2894879 ↗
14. Ganter · Nucl Instr Meth A · 2006 · 565 · 42310.1016/j.nima.2006.06.054 ↗
15. Jonge · Phil Trans R Soc Lond A · 2004 · 362 · 223910.1098/rsta.2004.1438 ↗
16. Tanemura · J Vac Sci Technol B · 2002 · 20 · 12210.1116/1.1430239 ↗
17. Sugie · Appl Phys Lett · 2001 · 78 · 257810.1063/1.1367278 ↗
18. Rao · Appl Phys Lett · 2000 · 76 · 381310.1063/1.126790 ↗
19. Bonard · Appl Phys A · 1999 · 69 · 24510.1007/s003390050998 ↗
20. Jorio · 2008 · vol. 111
21. Haga · Appl Phys Lett · 2004 · 84 · 220810.1063/1.1689757 ↗
22. Zhang · Rev Sci Instrum · 2005 · 76 · 09430110.1063/1.2041589 ↗
23. Liu · Appl Phys Lett · 2006 · 89 · 10311110.1063/1.2345829 ↗
24. Yue · Appl Phys Lett · 2002 · 81 · 35510.1063/1.1492305 ↗
25. Cheng · Rev Sci Instrum · 2004 · 75 · 326410.1063/1.1791313 ↗
26. Choi · Acta Phys Pol A · 2009 · 115 · 107810.12693/APhysPolA.115.1078 ↗
27. Kim · Mater Res Bull · 2014 · 58 · 10710.1016/j.materresbull.2014.05.004 ↗
28. Choi · J Kor Phys Soc · 2008 · 53 · 138810.3938/jkps.53.1388 ↗
29. 2009 · 6
30. Duy · Appl Surf Sci · 2009 · 256 · 106510.1016/j.apsusc.2009.05.106 ↗
31. Vaidya · Nuc Instr Meth Phys Res B · 2001 · 183 · 49710.1016/S0168-583X(01)00744-3 ↗
32. Goodsitt · Med Phys · 1997 · 24 · 1110.1118/1.597921 ↗
33. Nuclear associates 07–501 to 07–555 X-ray test patterns http://www.flukebiomedical.com.