Cylindrical hot cathode ionisation gauge – Construction and testing
Source abstract
Abstract
Hot cathode ionisation gauges are indispensable in measuring high and ultra-high vacuum. In the present work the construction details and the metrological evaluation of a novel gauge design — the cylindrical ionisation gauge is presented. With the aim of enhancing accuracy and stability both in the short and long term, details of the mechanical assembling of electrodes and precautions to minimize leakage currents influencing ion current measurement are described. Performance evaluations demonstrate high short-term stability, with linearity error, reproducibility, and repeatability values consistently below 1 %, placing the gauge at the same level as the most stable ionisation gauges. Operating across a pressure range of at least 6 orders of magnitude, the gauge exhibits low linearity error from high to ultra-high vacuum ranges. Its capability to measure pressures below 10 −9 mbar remains open and requires further investigation. • Novel cylindrical ionisation gauge design to achieve high accuracy and stability. • Robust construction and guarding electrodes that prevent disturbing leak currents. • High short-term stability: linearity error, repeatability and reproducibility <1 %. • No need for initial conditioning by exposing to high pressure of inert gases. • Operation at least in 6 orders of magnitude, has only been tested down to 10 −9 mbar.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Scientific Measurement and Uncertainty Evaluation · Plasma Diagnostics and Applications · Non-Destructive Testing Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Jousten · 2016 · 565
2. A review on hot cathode ionisation gauges with focus on a suitable design for measurement accuracy and stability10.1016/j.vacuum.2020.109545 ↗
3. Buckley · 1916 · vol. 2 · 683
4. Haas · 1998
5. Extension of the low pressure range of the ionization gauge10.1063/1.1745653 ↗
6. New hot-filament ionization gauge with low residual current10.1116/1.1492470 ↗
7. Ion gauge for vacuum pressure measurements below 1×10−10 torr10.1063/1.1720076 ↗
8. Ion spectroscopy gauge: total pressure measurements down to 10 −12 Pa with discrimination against electron‐stimulated‐desorption ions10.1116/1.577821 ↗
9. Bent belt-beam gauge: extending low-pressure measurement limits in a hot-cathode ionization vacuum gauge by combining multiple methods10.1116/1.3400233 ↗
10. Axial-symmetric transmission gauge: extension of its pressure measuring range and reduction of the electron stimulated desorption ion effect in ultrahigh vacuum10.1116/1.1901668 ↗
11. Stable and reproducible Bayard-Alpert ionisation gauge10.1116/1.578837 ↗
12. Electron trajectories in ionization gauges10.1088/0022-3727/3/7/316 ↗
13. An ionization gauge for measurement of ultra-high vacuum
14. Electrons on a straight path: a novel ionisation vacuum gauge suitable as reference standard10.1016/j.vacuum.2021.110239 ↗
15. Evaluation and metrological performance of a novel ionisation vacuum gauge suitable as reference standard10.1016/j.measurement.2023.112552 ↗
16. Development of a design for an ionisation vacuum gauge suitable as a reference standard10.1016/j.vacuum.2020.109884 ↗
17. Cylindrical hot cathode ionisation gauge – the concept and simulations10.1016/j.vacuum.2023.112701 ↗
18. Causes of nonstability and nonreproducibility in widely used Bayard–Alpert ionization gauges10.1116/1.578836 ↗
19. Comparison of ionization vacuum gauges close to their low pressure limit10.1016/j.vacuum.2022.111573 ↗
20. Hablanian · 2017
21. Novel ionisation vacuum gauge suitable as a reference standard: influence of primary electron trajectories on the operation10.1016/j.vacuum.2022.111041 ↗
22. Influence of ion induced secondary electron emission on the stability of ionisation vacuum gauges10.1016/j.vacuum.2020.109907 ↗
23. Stability tests of ionization gauges using two-stage flow-dividing system10.1016/j.vacuum.2009.09.011 ↗
24. Comparison of the stability of hot and cold cathode ionization gauges10.1116/1.1578654 ↗
25. Traceable low-current measurements for a novel ionization gauge suitable as reference standard
26. Sammartano · 2021
27. Outgassing behavior of different high-temperature resistant polymers10.1116/1.5001243 ↗