Bremsstrahlung converter system with target in vacuum
Source abstract
Abstract
Abstract The design of a bremsstrahlung converter for intense pulsed electron beam with total electron absorption and separated vacuum seal is investigated. The target of the converter is made of molybdenum with a thickness of 250 μm, isolated in vacuum by a titanium membrane of 60 μm thick. The article presents the experimental data of the converter tests, such as the dependence of the dose on the distance, the curve of dose rate, the image of the X-ray source obtained by the pinhole camera, and the thermal image of the converter exit window from the infrared camera. A dose of 10 mGy per pulse was demonstrated, with an instantaneous pulse dose rate of 0.1 MGy/s at a distance of 3 cm from the target plane. Reliable continuous operation for more than 1 million pulses at 10 pps has been experimentally achieved.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Radiotherapy Techniques · Radiation Effects and Dosimetry · Radiation Detection and Scintillator Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. Electron accelerators: history, applications, and perspectives10.1016/j.radphyschem.2012.12.008 ↗
2. Electron beam technology and other irradiation technology applications in the food industry, top
3. Application of electron beam water radiolysis for sewage sludge treatment—a review10.1007/s11356-020-10643-0 ↗
4. Bremsstrahlung converters for powerful industrial electron accelerators10.1016/j.radphyschem.2004.04.007 ↗
5. Target for production of X-rays10.1016/j.radphyschem.2004.03.056 ↗
6. An X-ray converter of a megavolt electron beam for powerful pulsed generators10.1007/s10786-005-0061-7 ↗
7. Efficiency of production of X rays10.6028/jres.005.053 ↗
8. Optimization of bremsstrahlung energy deposition10.1109/TNS.1976.4328594 ↗
9. A high repetition rate electron accelerator with a water Blumlein and a matching transformer10.1016/j.nima.2020.163565 ↗
10. Submicrosecond electron accelerator based on pulsed transformer10.1016/j.nima.2020.163951 ↗
11. Self-bearing membrane exit window with the separate anode for sub-microsecond electron accelerator: exit window for sub-microsecond e-accelerator10.1016/j.vacuum.2019.109111 ↗
12. Stopping-power & range tables for electrons, protons, and helium ions
13. Fluke · 2020
14. Infrared imaging diagnostics for intense pulsed electron beam10.1063/1.4928069 ↗
15. Energy response of EBT3 radiochromic films: implications for dosimetry in kilovoltage range10.1120/jacmp.v15i1.4439 ↗
16. Investigation of three radiation detectors for accurate measurement of absorbed dose in nonstandard fields10.1118/1.3392247 ↗
17. Absolute dosimetric characterization of Gafchromic EBT3 and HDv2 films using commercial flat-bed scanners and evaluation of the scanner response function variability10.1063/1.4954921 ↗
18. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry10.1088/0031-9155/54/4/017 ↗
19. PIN-diode diagnostics of pulsed electron beam for high repetition rate mode10.1088/1742-6596/830/1/012044 ↗
20. Scatter-hole cameras for X-rays and gamma rays10.1086/180230 ↗
21. X-ray pinhole camera resolution and emittance measurement10.1103/PhysRevSTAB.13.022805 ↗