Abstract

Abstract HIAF-BRing, a new multi-purpose accelerator facility of the High Intensity Heavy-Ion Accelerator Facility project, requires an extremely high vacuum lower than 10−9 Pa to fulfill the requirements of radioactive beam physics and high energy density physics. Use of large speed Titanium sublimation pump (TSP) in combination with Sputter ion pumps (SIP) is not always feasible due to space limitations. A novel combination pump, based on Non Evaporable getter (NEG) and a 10 l/s SIP (NEXTorr® D 2000-10) has been evaluated as it provides large speed in a more compact design. The two combination pumps (TSP + SIP and NEXTorr D 2000-10) have been tested by dynamic flow method to measure the ultimate pressure, the pumping speed and the suitability for HIAF. Test results show that both combination pumps can be used in the pressure range of 10−10 Pa. The ultimate pressure of TSP + SIP combination pump is slightly lower than NEXTorr D 2000-10, but the latter one has much larger sorption capacities (H2: 210200 Pa l vs 265 Pa. l; CO: 430 Pa. l vs 24 Pa. l), which means it is applicable to a wider pressure range. At the same time, after twenty activation cycles, the initial pumping speed of NEXTorr D 2000-10 for H2 and CO decreased less than 10% as compared with the initial pumping speed of the first activation, which meets the actual vacuum system requirement of HIAF. A dedicated vacuum chamber with collimator and NEXTorr D 2000-10 has been designed and manufactured to stabilize the dynamic vacuum by decreasing the heavy ion induced gas desorption and increasing the gas pumping speed. The static and dynamic vacuum pressure evolution has been simulated to verify the feasibility of the NEXTorr D 2000-10 used in the HIAF-BRing.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Particle accelerators and beam dynamics · Plasma Diagnostics and Applications · Superconducting Materials and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. High intensity heavy ion accelerator Facility(HIAF)in China10.1016/j.nimb.2013.08.046 ↗
2. Yang
3. Pressure profiles of the BRing based on the simulation used in the CSRm10.1016/j.nima.2017.04.017 ↗
4. The design of the spectrometer ring at the HIAF10.1016/j.nima.2017.08.017 ↗
5. The ultra-high vacuum system of HIRFL-CSR10.1016/S0042-207X(00)00447-4 ↗
6. The first prototype of the HIRFL-CSR UHV system10.1016/S0042-207X(02)00276-2 ↗
7. Li · 2017
8. P. Li, et al., Pressure Profiles Calculation for the CSRm and Bring, MOPR008, Proceedings of HB2016, Malmo, Sweden.
9. NEXTorr® Datasheets. https://www.saesgetters.com/products/nextorr-pumps). NEXTorr® is a SAES Getters internationally registered trademark.
10. Monte Carlo computations on molecular flow in pumping speed test domes10.1016/0042-207X(67)92176-8 ↗
11. Vacuum-calibration apparatus with pressure down to 10-10 Pa10.1116/1.3457934 ↗
12. Hoffman · 1998 · 367
13. Vacuum pressure rise with intense ion beams in RHIC
14. Towards the high intensity limit in the FAIR project present status and future challenges
15. Developments in the vacuum systems of AGS-RHIC10.1016/0042-207X(95)00043-7 ↗
16. Molecular desorption of stainless steel vacuum chambers irradiated with 4.2 MeV/u lead ions10.1103/PhysRevSTAB.6.013201 ↗
17. Ion-stimulated gas desorption yields of electropo -lished, chemically etched, and coated (Au, Ag, Pd, TiZrV) stainless steel vacuum chambers and St707 getter strips irradiated with 4.2 MeV/u lead ions10.1103/PhysRevSTAB.8.053201 ↗
18. Beam-loss induced pressure rise of Large Hadron Collider collimator materials irradiated with 158 GeV/u In49+ ions at the CERN Super Proton Synchrotron10.1103/PhysRevSTAB.7.103202 ↗
19. Ion-stimulated gas desorption yields and their dependence on the surface preparation of stainless steel
20. Introduction to MOLFLOW+: new GPU-based Monte Carlo for simulating molecular flows10.1116/1.3153280 ↗
21. J. Miertusova, Experience with the Extra Vacuum System during Commissioning. Sincrotron Trieste, S.P.A, Padriciano 99, 34012 Trieste, Italy.
22. M. Brouet, The Ultra-high Vacuum System for the Low Energy Antiproton Ring(LEAR) Design. Cost and Performances. CERN/PS-ML/83-42.
23. D. Blechschmidt, Basic Design of Vacuum System for 400GEV LSR with Normal Magnet. CERN-ISR-VA/75-29.
24. Construction and commissioning of the alternating-gradient synchrotron booster ultrahigh vacuum system10.1116/1.577987 ↗
25. P. Puppel, et al., Simulation of the long term beam intensity performance of the NEG-coated SIS18. Proceedings of HB2010,Morschach, Switzerland, 91-95.