journal article·2014-08

Vascular endothelial cell compatibility of superhard ternary Ti–Si–N coatings with different Si contents

Ming Zhang, Shengli Ma, Kewei Xu, Paul K. Chu

Vacuum· Volume 106
Publisher page

Abstract

Abstract Superhard ternary Ti–Si–N coatings with different Si atomic concentrations are deposited on titanium alloy substrates by arc-enhanced magnetron sputtering (AEMS) and the vascular endothelial cell compatibility is studied. In vitro studies show that the surface hydrophilicity and hemolysis are about the same as those of the titanium alloy control and platelet adhesion and protein adsorption tests suggest a close relationship between the surface energy and blood compatibility. Endothelial cells cultures reveal better proliferation and anti-platelet adhesion on the coatings compared to the titanium alloy control and the Ti–Si–N coating with 20 at% Si exhibits excellent endothelialization.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Metal and Thin Film Mechanics · Bone Tissue Engineering Materials · Polymer Surface Interaction Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. The blood and vascular cell compatibility of heparin-modified ePTFE vascular grafts10.1016/j.biomaterials.2012.09.046 ↗
2. Silicon nitride films for the protective functional coating: blood compatibility and biomechanical property study10.1016/j.jmbbm.2012.06.020 ↗
3. The covalent immobilization of heparin to pulsed-plasma polymeric allylamine films on 316L stainless steel and the resulting effects on hemocompatibility10.1016/j.biomaterials.2009.11.091 ↗
4. Antibacterial nano-structured titania coating incorporated with silver nanoparticles10.1016/j.biomaterials.2011.04.040 ↗
5. Biological response of endothelial cells to diamond-like carbon-coated NiTi alloy10.1002/jbm.a.33295 ↗
6. Corrosion resistance and hemocompatibility of multilayered Ti/TiN-coated surgical AISI 316L stainless steel10.1016/j.matlet.2005.06.058 ↗
7. Endothelial progenitor cells as therapeutic agents in the microcirculation: an update10.1016/j.atherosclerosis.2010.10.039 ↗
8. Coronary stents: a materials perspective10.1016/j.biomaterials.2006.11.042 ↗
9. Surface characterization of Ti-Si-C-ON coatings for orthopedic devices: XPS and Raman spectroscopy10.1016/j.solidstatesciences.2010.10.015 ↗
10. Influence of the surface morphology and microstructure on the biological properties of Ti–Si–C–N–O coatings10.1016/j.tsf.2010.05.050 ↗
11. Evolution of enhanced crystallinity and mechanical property of nanocomposite Ti–Si–N thin films using magnetron reactive co-sputtering10.1016/j.jallcom.2012.05.018 ↗
12. The tribological and structural characterization of nano-structured Ti–Si–N films coated by pulsed-d.c. plasma enhanced CVD10.1016/j.vacuum.2005.01.003 ↗
13. Influence of Si content on nano-structured Ti–Si–N films coated by pulsed-d.c. plasma enhanced CVD10.1016/j.surfcoat.2003.10.057 ↗
14. Induction of EPC homing on biofunctionalized vascular grafts for rapid in vivo self-endothelialization—a review of current strategies10.1016/j.biotechadv.2009.10.005 ↗
15. Serum protein adsorption and platelet adhesion on pluronic-adsorbed polysulfone membranes10.1016/S0142-9612(03)00186-8 ↗
16. The peroxynitrite donor 3-morpholinosydnonimine activates Nrf2 and the UPR leading to a cytoprotective response in endothelial cells10.1016/j.cellsig.2011.09.002 ↗
17. Thymidine phosphorylase inhibits vascular smooth muscle cell proliferation via upregulation of STAT310.1016/j.bbamcr.2012.05.025 ↗
18. Layer-by-layer assembly of chitosan and platelet monoclonal antibody to improve biocompatibility and release character of PLLA coated stent10.1002/jbm.a.33066 ↗
19. Proliferation, behavior, and cytokine gene expression of human umbilical vascular endothelial cells in response to different titanium surfaces10.1002/jbm.a.32539 ↗
20. The biocompatibility of titanium cardiovascular devices seeded with autologous blood-derived endothelial progenitor cells EPC-seeded antithrombotic Ti implants10.1016/j.biomaterials.2010.08.073 ↗
21. Study on properties and microstructure of Ti–Si–N coatings deposited in deep holes10.1016/j.surfcoat.2006.07.167 ↗
22. Protein adsorption on blood-contact membranes10.1016/S0376-7388(03)00313-2 ↗
23. A surface energetic criterion of blood compatibility of foreign surfaces10.1016/0021-9797(84)90055-9 ↗
24. Platelet activation behavior on nitrogen plasma-implanted silicon10.1016/j.msec.2006.11.005 ↗
25. Blood compatibility of surfaces with superlow protein adsorption10.1016/j.biomaterials.2008.07.039 ↗
26. Understanding protein adsorption phenomena at solid surfaces10.1016/j.cis.2010.12.007 ↗
27. Hemocompatibility of titanium-based coatings prepared by metal plasma immersion ion implantation and deposition10.1016/j.nimb.2006.12.169 ↗
28. In vitro investigation of protein adsorption and platelet adhesion on inorganic biomaterial surfaces10.1016/j.apsusc.2008.06.192 ↗
29. Biomaterial-associated thrombosis: roles of coagulation factors, complement, platelets and leukocytes10.1016/j.biomaterials.2004.01.023 ↗
30. Biomimetic control of vascular smooth muscle cell morphology and phenotype for functional tissue-engineered small-diameter blood vessels10.1002/jbm.a.32318 ↗
31. Deposition of titanium nitride (TiN) on Co–Cr and their potential application as vascular stent10.1016/j.apsusc.2011.10.149 ↗
32. Biofunctionalization of titanium surface with multilayer films modified by heparin-VEGF-fibronectin complex to improve endothelial cell proliferation and blood compatibility10.1002/jbm.a.34339 ↗
33. In vitro platelet adhesion on polymeric surfaces with varying fluxes of continuous nitric oxide release10.1002/jbm.a.31105 ↗
34. Comparison of endothelial cells grown on different stent materials10.1002/jbm.a.30595 ↗