Measurement of helium leak rates with temperature and pressure in RHIC
Source abstract
Abstract
The changes in helium leak rates with pressure and temperature from helium-cooled magnet vessels into insulating vacuum were measured. The leak rates increased by three orders of magnitude when the vessels were cooled from ambient temperature to 4.5 K. The changes in leak rates were found to be smaller than those of a viscous flow through a capillary tube.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Superconducting Materials and Applications · Magnetic confinement fusion research · Particle accelerators and beam dynamics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (9)
Show source-provided references
1. Bartelson · J Vac Sci Technol A · 1983 · A1 · 18710.1116/1.572071 ↗
2. Böhnert M, Brauer S, Hubert D, Ladage A, Cheng LI, Trines D. DESY HERA Report. 19–22, Dec., 1991 (unpublished).
3. Gröbner · Vacuum · 1995 · 46 · 79710.1016/0042-207X(95)00042-9 ↗
4. Hseuh · Vacuum · 1999 · 53 · 34710.1016/S0042-207X(98)00368-6 ↗
5. Hseuh HC, Davis R, Lee RC, Pate D, Smart L, Todd R, Weiss D, Zigrosser D. Proceedings of the 1999 Particle Acceleration Conference vol. 1, 1999. p. 557–61.10.1109/PAC.1999.795759 ↗
6. Dushman S, Lafferty JM. Scientific foundations of vacuum technique, 2nd ed. New York: Wiley, 1962, Sections 1.7, 2.1–2.4.
7. Sinharoy · J Vac Sci Technol · 1982 · 20 · 97810.1116/1.571657 ↗
8. Mallory · Nucl Instr and Meth · 1980 · 177 · 48110.1016/0029-554X(80)90061-0 ↗
9. Haselden · 1971