On long-term stability of an air piston gauge maintained at National Physical Laboratory, India
Source abstract
Abstract
Abstract The complexity of electronics and hardware in Ultrasonic Interferometer Manometer (UIM) along with a large amount of health and environmental hazardous mercury compelled most of the national metrological institutes (NMIs) to replace UIM with easy to operate and handle based on low-pressure range air piston gauge (APG). Since most of the NMIs have kept APG at the top of traceability chain (only a few have functional UIM), it is an urgent need of time to understand the qualitative change in the effective area at 23 °C (Ae) of piston-cylinder (p-c) assembly after long-term uses in measurement. The Ae of the p-c assembly of APG has been determined using UIM over the years during six in-house comparisons, which are found in the range of 10 ppm in the pressure range 20–120 kPa, which is well within the estimated uncertainties. The quality of p-c assembly was further checked by measuring fall-rate up to the full range of APG, which provides a maximum fall rate of 2.2 mm/min at 350 kPa. The present fall rate is very close to the manufacturer reported value, which suggests long-term stability of p-c assembly after 18 years in the calibration and measurement process. The uncertainties associated with Ae have been calculated using the law of propagation of uncertainty and Monte Carlo method and are found to be 9.8 ppm and 9.5 ppm at k = 2, respectively. The standard deviation of the mean of effective areas is in the range of 10−10 m2 to 10−11 m2 over 18 years, further, confirm the long-term stability of their consistency in the pressure measurement by p-c assembly.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Scientific Measurement and Uncertainty Evaluation · Flow Measurement and Analysis · Advanced Sensor Technologies Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (38)
Show source-provided references
1. Some laboratory applications of the low friction properties of the dry hypodermic syringe10.1063/1.1740950 ↗
2. Characterization of the piston gauge to assess the suitability of its use with several working fluids up to 5 MPa10.1063/1.1140026 ↗
3. A review of gas-operated piston gauges10.1088/0026-1394/30/6/007 ↗
4. Developments in the accurate measurement of high pressures10.1088/0026-1394/1/2/003 ↗
5. Correlation of hydrostatic and mechanical measurements of pressure
6. An intercomparison between a primary standard mercury barometer and a gas-operated pressure balance standard10.1088/0026-1394/15/2/004 ↗
7. Comparaison entre le manomètre à mercure de l’INM et la balance de pression de 400 kPa du LNE
8. The standard instruments of the PTB for the 5 MPa range of pressure measurement
9. Characterization of a pressure balance from dimensional measurements and from pressure comparison experiments
10. Analysis of mechanical pressure generators10.1088/0022-3735/11/7/023 ↗
11. Establishment of high pressure pneumatic standard up to 40 MPa at NPLI
12. Intercomparison of the effective areas of a pneumatic piston gauge determined by different techniques10.1088/0957-0233/4/3/001 ↗
13. Intercomparison of pressure standards in the barometric region
14. Intercomparison of hydraulic pressure measurements to 28 MPa using a single‐piston gauge in the controlled‐clearance, reentrant, and simple configurations10.1063/1.1142565 ↗
15. Establishing a continuous chain of traceability for pressure measurements up to 40 MPa10.1080/19315775.2013.11721630 ↗
16. Pavese · 2013
17. Stability of piston-cylinder assemblies from an experience of fifteen years10.1088/0026-1394/30/6/015 ↗
18. Role of national pressure and vacuum metrology in Indian industrial growth and their global metrological equivalence10.1007/s12647-018-0270-8 ↗
19. Contributions of national standards on the growth of barometric pressure and vacuum industries
20. Uncertainty evaluation and phase variation of ultrasonic interferometer manometer: a primary pressure and vacuum standard10.1016/j.vacuum.2019.04.023 ↗
21. A gas pressure scale based on primary standard piston gauges10.6028/jres.115.027 ↗
22. Characterization of the new 1 GPa piston-cylinder assembly of PTB10.1016/j.measurement.2018.10.097 ↗
23. Metrological characterization of non-rotating low-pressure piston-cylinder unit system10.1088/1742-6596/1065/16/162001 ↗
24. Computation of the effective area and associated uncertainties of non-rotating piston gauges FPG and FRS10.1088/1681-7575/aaee18 ↗
25. An integrated and automated calibration system for pneumatic piston gauges10.1016/j.measurement.2018.10.050 ↗
26. Primary pressure standard based on piston-cylinder assemblies. Calculation of effective cross sectional area based on rarefied gas dynamics10.1088/0026-1394/53/5/1177 ↗
27. Sharipov · 2016
28. Determination of the effective area of piston-cylinder assemblies using rarefied gas flow model
29. Evaluation of uncertainty in the effective area and distortion coefficients of air piston gauge using Monte Carlo method10.1007/s12647-019-00336-6 ↗
30. Uso de Planilhas Eletrônicas para Implementação do Método de Monte Carlo para Estimativa de Incerteza de Medição
31. On a Monte Carlo method for measurement uncertainty evaluation and its implementation10.1088/0026-1394/51/4/S176 ↗
32. 2008
33. Ultrasonic manometers for low and medium vacua under development at the National Bureau of Standards10.1116/1.569158 ↗
34. Measurement uncertainty estimation in real experimental conditions of ultrasonic interferometer manometer established at NPL, India10.1016/j.vacuum.2006.12.015 ↗
35. The speed of sound in a mercury ultrasonic interferometer manometer10.1088/0026-1394/24/3/003 ↗
36. Precise measurements of the density of mercury at 20 degrees C II. Content method
37. Density, thermal expansion and compressibility of mercury10.1088/0026-1394/30/6/023 ↗
38. Fluke