article·2012-05-11

Time-dependent changes in morphology and resistance of W/TiN/Ti metal lines upon applying voltage pulses

Deok‐kee Kim, Soo-Jung Hwang

Publisher page

Abstract

Abstract Transient current profiles, measured while applying voltage pulses to W/TiN/Ti metal lines, showed two different stages. In the first stage, the transient current decreased due to both structural changes associated with Ti/W diffusion and the positive temperature coefficient of resistance of polycrystalline W/TiN/Ti. In the second stage, the transient current remained approximately constant due to the effect of morphological and microstructural changes counter-balanced by the thermal expansion of W near the melting temperature and the latent heat of fusion of W. Asymmetric electromigration and symmetric thermomigration fluxes resulted in the asymmetric metal line failure location near the anode.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Copper Interconnects and Reliability · Metal and Thin Film Mechanics · Electronic Packaging and Soldering Technologies