Effects of (002) β-Ta barrier on copper chemical mechanical polishing behavior
Source abstract
Abstract
Abstract This study proposes that the corrosion resistance of copper film correlates well with underlying barrier's orientation. To test the hypothesis, we performed X-ray diffraction, conducted copper removal rate experiments after chemical mechanical polishing, and tested static potentiodynamic polarization. The results all show that copper deposited on strongly (002) oriented β-Ta barrier layer demonstrated better chemical resistance against surface reaction with the slurry for strong copper (111) orientation. The findings were consistent with the result of the chronoamperometric test at 0.3 V in which the more passive film formed on the composite film with (002) β-Ta underlying barrier.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Surface Polishing Techniques · Integrated Circuits and Semiconductor Failure Analysis · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.