Microstructural and corrosivity changes induced by nitrogen ion implantation on chromium films
Source abstract
Abstract
Abstract The chromium thin films were prepared using ion beam deposition on stainless steel 304. The chromium films were implanted by nitrogen ions after deposition at doses in the range of 4.5 × 1017 to 2.7 × 1018 N+/cm2 and energy of 30 keV. The formation of nitride phases and corrosion behavior after nitrogen implantation were characterized by XRD and corrosion test, respectively. The results show that corrosion resistance rise, reach to a maximum at dose of 1.8 × 1018, and then fall down at higher doses. In addition, the effect of corrosion tests was analyzed using scanning electron microscopy (SEM).
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Ion-surface interactions and analysis · Diamond and Carbon-based Materials Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References