The influence of air and vacuum thermal treatments on the NO2 gas sensitivity of WO3 thin films prepared by thermal evaporation
Source abstract
Abstract
Abstract WO 3 films with thickness of 80 nm have been thermally evaporated onto Si 3 N 4 /Si substrates. The films have been initially treated in oxygen by a 24-h-long annealing at 300°C and 500°C. XPS measurements, to follow W 4f, O 1s peaks and the valence band, have been performed on these samples as prepared and after successive ultra high vacuum (UHV) thermal treatments. We observed that the UHV annealing procedure produces a lack of oxygen at the surface of the as deposited and 300°C annealed samples strongly modifying the W 4f peak and producing the increase of metallic states at the Fermi edge, while very few modifications have been observed in the 500°C sample. The films submitted to UHV thermal treatments have been also investigated as resistive gas sensors towards NO 2 . We observed a lowering of the base resistance and a decrease of the sensitivity properties with respect to the corresponding non-vacuum treated samples.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Transition Metal Oxide Nanomaterials · Gas Sensing Nanomaterials and Sensors · Analytical Chemistry and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References
Reference metadata was not supplied for this record.