journal article·2020-11

Revealing the theoretical assumptions of the trap-depth distribution model in the thermoluminescence theory

A.M. Sadek

Thin Solid Films· Volume 714
Publisher page

Abstract

Abstract The theoretical assumptions of the analytical expressions characterizing the thermoluminescence glow-peak arising from a continuous trap-depth distribution have been investigated. The sets of the differential equations governing the electrons’ transitions within a continuous trap-depth distribution during the irradiation and heating stages have been numerically solved. The analytical expressions are essentially based on a theoretical assumption that correlates the concentrations of the trapped electrons with the distribution of the trap depths in the bandgap. This correlation could not be considered in the numerical solution, since the irradiation stage is entirely independent of the trap depth. Thus, the final values of the instantaneous trap-filling functions of the irradiation stage do not depend on the trap depth, but rather on the trap capacity and the trapping probability coefficient. Consequently, in the numerical solution, the distribution of the trap depths and the distribution of the trapped electrons are independent. This inconsistency between the numerical solution and the analytical expression has led to differences in the shape of the thermoluminescence glow peaks resulting from the same trap-depth spectrum.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Thermal Radiation and Cooling Technologies · Atmospheric chemistry and aerosols · Luminescence Properties of Advanced Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Thermoluminescence and phosphorescence with a continuous distribution of activation energies10.1016/0022-2313(89)90023-9 ↗
2. Experimental study of the mechanism of thermoluminescence in irradiated sodium chloride10.1063/1.1742071 ↗
3. TL and F centers, I.
4. Thermoluminescence and F-centers. II.10.1103/PhysRev.114.956 ↗
5. Interpretation of thermoluminescence and thermally stimulated conductivity experiments: part I: extensions of the conventional model10.1016/0022-2313(78)90013-3 ↗
6. McKeever · 1985
7. Phosphorescence and electron traps, I. The study of trap distribution
8. Nonequilibrium Steady-State Statistics and Associated Effects for Insulators and Semiconductors Containing an Arbitrary Distribution of Traps10.1103/PhysRevB.4.502 ↗
9. Phosphorescence and electron traps. II. The interpretation of long-period phosphorescence10.1098/rspa.1945.0025 ↗
10. Recombination processes in insulators and semiconductors10.1103/PhysRev.97.322 ↗
11. Analysis of glow curves for a material containing distributed trap levels10.1016/0040-6090(74)90031-5 ↗
12. Thermoluminescence from a distribution of trapping levels in UV irradiated calcite10.1016/1350-4487(95)00310-X ↗
13. Thermoluminescence kinetic parameters of basaltic rock samples due to contious trap distribution10.1016/j.nima.2004.04.208 ↗
14. Thermoluminescence glow curve deconvolution for discrete and continuous10.1016/j.apradiso.2019.108843 ↗
15. Single level isothermal TL-decay (with energy distribution and retrapping)10.1016/1359-0189(88)90045-3 ↗
16. Thermoluminescence glow-curve deconvolution functions for mixed order of kinetics and continuous trap distribution10.1016/S0168-9002(99)00876-1 ↗
17. Comment on the paper “Thermoluminescence glow-curve deconvolution functions for mixed order of kinetics and continuous trap distribution
18. Thermoluminescence kinetic analysis of basaltic rocks using a generalized model for exponential distribution of activation energies10.1016/j.nimb.2007.09.021 ↗
19. A critical look at the kinetic parameter values used in simulating the thermoluminescence glow-curve10.1016/j.jlumin.2016.12.002 ↗
20. Evolution of the trapped charge distribution due to trap emptying processing in a natural aluminosilicate10.1093/rpd/nci522 ↗
21. On the validity and accuracy of the initial rise method investigated using realistically simulated thermoluminescence curves10.1016/j.radmeas.2018.07.010 ↗
22. Behaviour of the fractional glow technique with first-order detrapping processes, traps distributed in energy or frequency factor10.1002/pssa.2210490253 ↗
23. 2008
24. On the calculation of activation energies and frequency factors from glow curves10.1063/1.1657437 ↗
25. Press · 2007
26. Solving index-1 DAEs in MATLAB and Simulink10.1137/S003614459933425X ↗
27. Thermoluminescence glow curves for distributed trap levels10.1016/0040-6090(75)90295-3 ↗
28. Properties of the thermoluminescence glow peaks simulated by the interactive multiple-trap system (IMTS) model10.1002/pssb.201451406 ↗
29. The shift of the thermoluminescnece peak maximum temperature versus heating rate, trapping fillinf and trap emptying: predictions, experimental verification and comparison10.1016/j.physb.2019.411754 ↗
30. The analysis of dosimetric thermoluminescent glow peak of CaF2:mn after \beta-irradiation10.1016/j.nimb.2007.02.104 ↗
31. The analysis of thermoluminescence glow peaks of CaF_2:dy (TLD-200) after \beta-irradiation10.1088/0022-3727/35/20/311 ↗
32. The thermoluminescence properties of natural CaF2 after \beta-irradiation10.1016/j.nimb.2007.09.018 ↗
33. Revealing trap depth distributions in persistent phosphors
34. Nonlinear dose dependence of TL and LM-OSL within the one trap-one center model10.1016/j.radmeas.2009.12.038 ↗
35. Sublinear dose dependence of thermoluminescence and optically stimulated luminescence prior to the approach to saturation level10.1016/j.radmeas.2009.03.003 ↗