article·2004-11-08

Cu-penetration induced breakdown mechanism for a-SiCN

C. W. Chen, Po‐Tsun Liu, Tien‐Chun Chang, Jyun-Bao Yang, T. M. Tsai, H. H. Wu, Tseung‐Yuen Tseng

Publisher page

Abstract

Wehaveinvestigated theleakage mechanismofamorphousSiCN(a-SiCN) filmsafter bias-temperature-stress (BTS)withCuelectrode.The leakage current became very large and breakdown due to the Cu ions penetration after strict BTS condition. The distribution profile of Cu penetrationwasdepictedbySIMSspectrum.ItisapparentthatCuionspenetratedintothea-SiCNfilmandevenreachedtotheinterfacebetween a-SiCN/Si due to BTS. The Cu ions existing in a-SiCN would be taken as trap states and could enhance the carriers to transport. The main characteristics of post-breakdown a-SiCN followed the space-charge-limited current (SCLC) mechanism at 298 K. With decreasing the temperature to 100K,theFowler–Nordheim tunneling dominatedthe conductionin mediumfields.However,electrons obeyed theSCLC again inhighfields(N3.3MV/cm)at100K.Wepurposeaphysicalmodeltointerprettheleakagemechanismofbreakdowna-SiCNfilmsduetoCuions.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Semiconductor materials and devices · Copper Interconnects and Reliability · Silicon Carbide Semiconductor Technologies