journal article·2015-08

Surface chemistry and cytotoxicity of reactively sputtered tantalum oxide films on NiTi plates

K. McNamara, O. Kolaj-Robin, S. Belochapkine, F. Laffir, A.A. Gandhi, S.A.M. Tofail

Thin Solid Films· Volume 589
Publisher page

Abstract

Abstract NiTi, an equiatomic alloy containing nickel and titanium, exhibits unique properties such as shape memory effect and superelasticity. NiTi also forms a spontaneous protective titanium dioxide (TiO 2 ) layer that allows its use in biomedical applications. Despite the widely perceived biocompatibility there remain some concerns about the sustainability of the alloy's biocompatibility due to the defects in the TiO 2 protective layer and the presence of high amount of sub-surface Ni, which can give allergic reactions. Many surface treatments have been investigated to try to improve both the corrosion resistance and biocompatibility of this layer. For such purposes, we have sputter deposited tantalum (Ta) oxide thin films onto the surface of the NiTi alloy. Despite being one of the promising metals for biomedical applications, Ta, and its various oxides and their interactions with cells have received relatively less attention. The oxidation chemistry, crystal structure, morphology and biocompatibility of these films have been investigated. In general, reactive sputtering especially in the presence of a low oxygen mixture yields a thicker film with better control of the film quality. The sputtering power influenced the surface oxidation states of Ta. Both microscopic and quantitative cytotoxicity measurements show that Ta films on NiTi are biocompatible with little to no variation in cytotoxic response when the surface oxidation state of Ta changes.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Shape Memory Alloy Transformations · Titanium Alloys Microstructure and Properties · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (47)

Show source-provided references
1. An overview of Nitinol medical applications
2. Shape memory alloys: properties and biomedical applications10.1007/s11837-000-0082-4 ↗
3. Medical shape memory alloy applications—the market and its products10.1016/j.msea.2003.10.326 ↗
4. Surface, corrosion and biocompatibility aspects of Nitinol as an implant material
5. Critical overview of Nitinol surfaces and their modifications for medical applications10.1016/j.actbio.2008.01.013 ↗
6. Electrochemical and surface characterization of a nickel–titanium alloy10.1016/S0142-9612(97)00210-X ↗
7. Localized corrosion behavior in human body fluids of commercial NiTi orthodontic wires10.1016/S0142-9612(98)90233-2 ↗
8. Cytotoxic, allergic and genotoxic activity of a nickel–titanium alloy10.1016/S0142-9612(97)00041-0 ↗
9. Biocompatibility of nickel–titanium shape memory metal and its corrosion behavior in human cell cultures10.1002/(SICI)1097-4636(19970615)35:4<451::AID-JBM5>3.0.CO;2-G ↗
10. Biocompatibility of Nitinol for medical applications
11. Corrosion behavior of Nitinol wires in body fluid environment10.1002/jbm.a.10099 ↗
12. Influence of Nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release10.1002/jbm.a.30720 ↗
13. Allergies to dental metals
14. Density functional theory simulation of titanium migration and reaction with oxygen in the early stages of oxidation of equiatomic NiTi alloy10.1016/j.biomaterials.2010.01.060 ↗
15. Surface treatment of NiTi for medical applications10.1080/13645700410020278 ↗
16. Improvement in corrosion resistance of NiTi by anodization in acetic acid10.1016/j.matlet.2006.09.020 ↗
17. Microstructural characterization of oxide film formed on NiTi by anodization in acetic acid10.1016/j.jallcom.2006.08.020 ↗
18. A study on the electrodeposition of tantalum on NiTi alloy in an ionic liquid and corrosion behaviour of the coated alloy10.1016/j.elecom.2005.06.007 ↗
19. Preparation and characterization of hydroxyapatite/titania composite coating on NiTi alloy by electrochemical deposition10.1016/j.surfcoat.2010.11.049 ↗
20. Electrodeposition of polypyrrole onto NiTi and the corrosion behaviour of the coated alloy10.1016/j.corsci.2009.09.008 ↗
21. Corrosion property of TiNi shape memory alloys coated with tantalum10.1023/B:JMSL.0000004648.40757.56 ↗
22. Surface characteristics and corrosion resistance properties of TiNi shape memory alloy coated with Ta10.1016/j.surfcoat.2004.01.012 ↗
23. Surface modification of NiTi alloy with tantalum to improve its biocompatibility and radiopacity10.1007/s10853-006-0096-6 ↗
24. The biocompatibility of the tantalum and tantalum oxide films synthesized by pulse metal vacuum arc source deposition10.1016/j.nimb.2005.08.002 ↗
25. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium10.1016/S0142-9612(00)00275-1 ↗
26. Analysis of magnetron-sputtered tantalum coatings versus electrochemically deposited tantalum from molten salt10.1016/S0257-8972(99)00337-0 ↗
27. Structures of tantalum pentoxide thin films formed by reactive sputtering of Ta metal10.1016/0040-6090(94)06402-4 ↗
28. The effect of thermal treatment on the structure of tantalum oxide films grown on titanium10.1134/1.1760866 ↗
29. Effect of growth and annealing temperatures on crystallization of tantalum pentoxide thin film prepared by RF magnetron sputtering method10.1016/j.jallcom.2008.07.126 ↗
30. X-ray study of the surface morphology of crystalline and amorphous tantalum peroxide thin films prepared by RF magnetron sputtering10.1016/S0022-0248(01)01950-9 ↗
31. Structural and electrical properties of radio frequency magnetron sputtered tantalum oxide films: influence of post-deposition annealing10.1016/j.mssp.2010.08.002 ↗
32. Structure formation upon reactive direct current magnetron sputtering of transition metal oxide films10.1063/1.1777412 ↗
33. Rapid thermal processed thin films of reactively sputtered Ta2O510.1016/0040-6090(94)06322-2 ↗
34. Effects of deposition parameters on tantalum films deposited by direct current magnetron sputtering in Ar–O2 mixture10.1016/j.apsusc.2011.10.012 ↗
35. The mechanism of reactive sputtering10.1007/BF00549739 ↗
36. X-ray analyses of thermally grown and reactively sputtered oxide films on NiTi alloy10.1016/j.nimb.2011.07.106 ↗
37. ASTM F813-07 · 2007
38. Neutral red uptake assay for the estimation of cell viability/cytotoxicity10.1038/nprot.2008.75 ↗
39. The influence of surface oxides on the distribution and release of nickel from Nitinol wires10.1016/j.biomaterials.2008.10.014 ↗
40. Oxidation of a NiTi Alloy10.1002/sia.740150602 ↗
41. Surface oxidation of NiTi shape memory alloy10.1016/S0142-9612(02)00244-2 ↗
42. Microstructure of surface and subsurface layers of a Ni–Ti shape memory microwire10.1017/S1431927609090059 ↗
43. Oxidation behaviour of equiatomic TiNi alloy in high temperature air environment10.1016/0921-5093(96)10409-3 ↗
44. Surface oxidation of NiTi shape memory alloy in a boiling aqueous solution containing hydrogen peroxide10.1016/j.msea.2005.11.010 ↗
45. Surface structure and corrosion resistance of short-time heat-treated NiTi shape memory alloy10.1016/j.apsusc.2010.08.097 ↗
46. Analysis of components depth profile at the interface of Ti6242 alloy and TiNi coatings after high temperature oxidation in air10.1002/pssc.200983792 ↗
47. New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility10.1002/jbm.b.30441 ↗