Ceramic coating for delayed degradation of Mg-1.2Zn-0.5Ca-0.5Mn bone fixation and instrumentation
Source abstract
Abstract
Abstract Mg and its alloys possess a biodegradable nature that has recently made them attractive for potential applications in biomedical devices that are expected to degrade and bioresorb completely in-vivo after the healing of the body tissue. We have developed an Mg-Zn-Ca-Mn alloy containing biocompatible alloying elements, and a heat treatment process that is likely to improve mechanical stability and absorption properties during bone healing and reliably resorb following the healing of a reconstructed skeletal segment. Our objective in this work is to investigate the use of a composite ceramic-based coating to delay the degradation (weakening) of our strengthened alloy for several months to avoid loss of mechanical properties during the healing process. The heat-treated alloy samples were coated using plasma electrolytic oxidation (PEO) and a sol-gel (layer-by-layer) coating techniques to achieve improved corrosion resistance. The coated samples were characterized for their morphological and corrosion characteristics using scanning electron microscope (SEM), X-ray diffraction analysis (XRD), and in vitro corrosion testing methods. These in vitro corrosion studies showed a significant improvement in the corrosion resistance of the PEO/sol-gel coated alloy. The PEO/sol-gel coated alloy samples lost only approx. 3% of their strength, after 8 weeks of immersion in a corrosive environment, compared to 30% loss for the uncoated alloy samples under the same conditions. The results of this study suggest that it should be possible to maintain the mechanical integrity of Mg-based implants inside the body for the desired 6–9 month period and longer if that becomes useful.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Aluminum Alloys Composites Properties · Hydrogen Storage and Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Resorbable bone fixation alloys, forming, and post-fabrication treatments10.1016/j.msec.2016.09.069 ↗
2. Recent advances on the development of magnesium alloys for biodegradable implants10.1016/j.actbio.2014.07.005 ↗
3. Surface design of biodegradable magnesium alloys—a review10.1016/j.surfcoat.2012.10.009 ↗
4. New, fast corroding high ductility Mg–Bi–Ca and Mg–Bi–Si alloys, with no clinically observable gas formation in bone implants10.1016/j.mseb.2011.07.011 ↗
5. The formation of hydrogen peroxide during corrosion reactions10.1149/1.3500289 ↗
6. Fracture fixation 110.1148/rg.236035159 ↗
7. Strategies to improve the corrosion resistance of microarc oxidation (MAO) coated magnesium alloys for degradable implants: prospects and challenges10.1016/j.pmatsci.2013.08.002 ↗
8. Microstructural, mechanical and corrosion characteristics of heat-treated Mg-1.2 Zn-0.5 Ca (wt%) alloy for use as resorbable bone fixation material10.1016/j.jmbbm.2017.01.005 ↗
9. Electrodeposition of hydroxyapatite coating on Mg-4.0 Zn-1.0 Ca-0.6 Zr alloy and in vitro evaluation of degradation, hemolysis, and cytotoxicity10.1002/jbm.a.34042 ↗
10. Effects of sealing treatment on corrosion resistance and degradation behavior of micro-arc oxidized magnesium alloy wires10.1016/j.apsusc.2013.01.175 ↗
11. Loss of mechanical properties in vivo and bone–implant interface strength of AZ31B magnesium alloy screws with Si-containing coating10.1016/j.actbio.2013.12.020 ↗
12. In vitro investigation of biodegradable polymeric coating for corrosion resistance of mg-6Zn-Ca alloy in simulated body fluid10.1016/j.msec.2014.05.035 ↗
13. Electrochemical performance of microarc oxidation films formed on AZ91D magnesium alloy in silicate and phosphate electrolytes10.1016/j.surfcoat.2005.05.039 ↗
14. Investigation of plasma electrolytic oxidation process on AZ91D magnesium alloy10.1016/j.cap.2007.12.007 ↗
15. Corrosion mechanism and model of pulsed DC microarc oxidation treated AZ31 alloy in simulated body fluid10.1016/j.apsusc.2012.03.016 ↗
16. Strategies to improve the corrosion resistance of microarc oxidation (MAO) coated magnesium alloys for degradable implants: prospects and challenges10.1016/j.pmatsci.2013.08.002 ↗
17. Deposition of microarc oxidation–polycaprolactone duplex coating to improve the corrosion resistance of magnesium for biodegradable implants10.1016/j.tsf.2014.04.004 ↗
18. In vitro analysis of electrophoretic deposited fluoridated hydroxyapatite coating on micro-arc oxidized AZ91 magnesium alloy for biomaterials applications
19. Electrochemical corrosion behavior of composite MAO/sol–gel coatings on magnesium alloy AZ91D using combined micro-arc oxidation and sol–gel technique10.1016/j.jallcom.2008.06.135 ↗
20. Film characteristics of anodic oxidized AZ91D magnesium alloy by applied power10.1002/sia.3058 ↗
21. Fabrication and characterization of bioactive composite coatings on Mg–Zn–Ca alloy by MAO/sol–gel10.1007/s10856-011-4349-9 ↗
22. Improved anticorrosion of magnesium alloy via layer-by-layer self-assembly technique combined with micro-arc oxidation10.1016/j.matlet.2012.02.016 ↗
23. Controlling the degradation rate of AZ91 magnesium alloy via sol–gel derived nanostructured hydroxyapatite coating10.1016/j.msec.2013.05.014 ↗
24. Composite coating prepared by micro-arc oxidation followed by sol–gel process and in vitro degradation properties10.1016/j.apsusc.2011.11.011 ↗
25. In vitro degradation of AZ31 magnesium alloy coated with nano TiO2 film by sol–gel method10.1016/j.apsusc.2011.03.148 ↗
26. Immobilization of bovine serum albumin on TiO2 film via chemisorption of H3PO4 interface and effects on platelets adhesion10.1016/j.apsusc.2007.10.107 ↗
27. Functionality of Ti-O thin films doped by phosphorus: wettability, semiconductor performance and blood compatibility10.4028/www.scientific.net/MSF.610-613.1017 ↗
28. The evolution of cardiovascular stent materials and surfaces in response to clinical drivers: a review10.1016/j.actbio.2008.11.012 ↗
29. Predicting the biodegradation of magnesium alloy implants: modeling, parameter identification, and validation10.3390/bioengineering5040105 ↗
30. Mechanical and in vitro corrosion properties of a heat-treated Mg-Zn-Ca-Mn alloy as a potential bioresorbable material
31. Fabrication and characterization of a biocompatible coating formed on a heat-treated magnesium alloy using micro-arc oxidation
32. Aminopropyltriethoxysilane-mediated surface functionalization of hydroxyapatite nanoparticles: synthesis, characterization, and in vitro toxicity assay
33. Jones · 1992
34. Application of hydroxyapatite-sol as drug carrier
35. Aqueous impregnation of porous β-tricalcium phosphate scaffolds10.1016/j.actbio.2010.01.018 ↗
36. Enhancement of osteogenesis and biodegradation control by Brushite coating on Mg–Nd–Zn–Zr alloy for mandibular bone repair10.1021/am506543a ↗
37. Mg and Mg alloys: how comparable are in vitro and in vivo corrosion rates? A review10.1016/j.actbio.2014.11.048 ↗