The clinical efficacy of extracorporeal membrane oxygenation (ECMO) is largely determined by the mechanical properties and gas permeance of membrane materials. Current warp knitting methods can harm poly(4-methyl-1-pentene) (PMP) hollow fiber membranes because the tension from the yarns affects their ability to provide oxygen. This study systematically investigates the influence of three representative warp knitting structures—pillar stitch, tricot stitch, and cord stitch—on PMP membrane integrity using a design-based approach. A novel multiparameter model, the Membrane Damage Index (MDI), is proposed to quantify membrane damage across structural variants. Experimental results reveal that the pillar stitch configuration significantly reduces fracture strength loss (7.8%), CO 2 flux reduction (12.7%), and outer diameter compression (7.56%) by optimizing stress distribution and minimizing the underlap length (0.97 mm). Nonlinear regression analysis of the data led to the development of an MDI model ( R 2 = 0.992), highlighting the importance of the number of needle back traversal stitches ( n ) in minimizing membrane damage. This study offers a theoretical framework and optimization strategy for developing low-damage ECMO membranes, ultimately enhancing clinical efficacy and the long-term durability of ECMO technology.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Mechanical Circulatory Support Devices · Polymer Surface Interaction Studies · Membrane Separation Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Engineering Research Center for Knitting Technology, Ministry of Education, Jiangnan University, China

College of Textile and Fashion, Hunan Institute of Engineering, Xiangtan, Hunan, 411104, PR China

National Innovation Center for Advanced Medical Devices, Shenzhen, Guangdong, China

References (36)

Show source-provided references
1. 10.1186/s13054-016-1570-410.1186/s13054-016-1570-4 ↗
2. 10.1093/eurheartj/ehv19410.1093/eurheartj/ehv194 ↗
3. 10.1016/j.jacc.2018.11.03810.1016/j.jacc.2018.11.038 ↗
4. 10.1161/CIRCULATIONAHA.122.06294910.1161/CIRCULATIONAHA.122.062949 ↗
5. 10.1097/MAT.000000000000117310.1097/MAT.0000000000001173 ↗
6. 10.1097/MAT.000000000000123010.1097/MAT.0000000000001230 ↗
7. 10.1007/s00134-020-06248-310.1007/s00134-020-06248-3 ↗
8. 10.1016/j.memsci.2008.09.05310.1016/j.memsci.2008.09.053 ↗
9. 10.1007/s00134-020-06331-910.1007/s00134-020-06331-9 ↗
10. 10.1016/j.memsci.2018.05.04010.1016/j.memsci.2018.05.040 ↗
11. 10.1016/j.memsci.2024.12289110.1016/j.memsci.2024.122891 ↗
12. 10.1016/j.memsci.2022.12035910.1016/j.memsci.2022.120359 ↗
13. 10.1016/j.advmem.2023.10006710.1016/j.advmem.2023.100067 ↗
14. 10.1177/1528083724126862810.1177/15280837241268628 ↗
15. 10.1007/s42114-021-00244-x10.1007/s42114-021-00244-x ↗
16. 10.1177/026765911456755610.1177/0267659114567556 ↗
17. 10.3390/membranes1107052910.3390/membranes11070529 ↗
18. 10.1016/S0022-5223(19)41180-X10.1016/S0022-5223(19)41180-X ↗
19. Xi L, Jia W, Liu H, et al. Research on the PID series control system of a weft-insertion warp knitting machine based on kinematics. J Text Inst 2025; ▪: ▪. DOI: 10.1080/00405000.2025.2460266.
20. 10.1016/j.jmrt.2024.02.05110.1016/j.jmrt.2024.02.051 ↗
21. 10.1002/pssb.20108421610.1002/pssb.201084216 ↗
22. 10.1177/004051751557833410.1177/0040517515578334 ↗
23. 10.1177/002199830504709910.1177/0021998305047099 ↗
24. 10.1177/004051750505473110.1177/0040517505054731 ↗
25. 10.1177/1528083723120339910.1177/15280837231203399 ↗
26. 10.1177/152808370910293810.1177/1528083709102938 ↗
27. 10.3390/membranes1301001410.3390/membranes13010014 ↗
28. 10.1177/00405175030730080510.1177/004051750307300805 ↗
29. 10.1007/s10853-023-08544-x10.1007/s10853-023-08544-x ↗
30. 10.1177/00405175970670110810.1177/004051759706701108 ↗
31. 10.1177/0040517523115453410.1177/00405175231154534 ↗
32. 10.1177/0040517521101383610.1177/00405175211013836 ↗
33. 10.1177/004051752093737210.1177/0040517520937372 ↗
34. 10.1109/ACCESS.2022.314983810.1109/ACCESS.2022.3149838 ↗
35. 10.1177/004051751452856210.1177/0040517514528562 ↗
36. W J Chen S Zheng H et al. An integrated device for testing the performance of breathable membranes and its operating method. Patent CN202111177185.X (China 2023).