journal article·2026-08

Design and evaluation of sportswear integrated with electrical muscle stimulation

Xiaolu Li, Chi-Wai Kan, Joanne Yip, Qian Zhang

Textile Research Journal· Volume 96· Issue 15-16
Publisher page

Abstract

Electrical muscle stimulation (EMS) technology integrated into sportswear offers promising potential for enhanced muscle building. However, there is limited understanding of strategic electrical parameters essential to maximize effectiveness. Therefore, this study aimed to design and develop an EMS-integrated sportswear capable of delivering targeted stimulation, and to evaluate its effectiveness through surface electromyography (sEMG) experiments. The root mean square (RMS) values of sEMG signals were analyzed, and a two-way repeated measure analysis of variance (ANOVA) with Tukey post hoc test was employed to examine the effects of varying electrical stimulation on muscle activation in the gastrocnemius, rectus femoris, and biceps femoris over nine time points ( t 1 to t 9 ). The findings indicated that the activation patterns varied across different muscle groups in response to changes in frequency, voltage, and duration of stimulation. Notably, higher frequencies (70 and 100 Hz) significantly enhanced muscle activation in the rectus femoris and biceps femoris at earlier stages, while the gastrocnemius muscle demonstrated limited response. At higher voltages (10.8 and 13.5 V), the rectus femoris and biceps femoris exhibited strong activation across most time points, whereas the gastrocnemius remained unresponsive. Conversely, lower frequencies and voltages resulted in delayed activation responses. Perceived exertion increased over time across all conditions. In addition, tactile feedback was observed earlier at higher voltages (400 seconds at 13.5 V) and higher frequencies (200 seconds at 100 Hz), indicating faster neural responses at these levels. These findings provide critical insights for optimizing EMS-integrated sportswear designs, enhancing their practical application in sports performance enhancement and rehabilitative healthcare.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Muscle activation and electromyography studies · Advanced Sensor and Energy Harvesting Materials · Tactile and Sensory Interactions

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Fashion and Design, Donghua University, Shanghai, China

School of Fashion and Textiles, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China

Key Laboratory of Clothing Design and Technology, Donghua University, Ministry of Education, Shanghai, China

Funding

PuJiang Talents Programme · Fundamental Research Funds for the Central Universities · Humanities and Social Sciences of the Ministry of Education of China

References (43)

Show source-provided references
1. 10.11114/jets.v6i9.334710.11114/jets.v6i9.3347 ↗
2. 10.3389/fnhum.2014.0023410.3389/fnhum.2014.00234 ↗
3. 10.1080/17461391.2020.183861710.1080/17461391.2020.1838617 ↗
4. 10.1053/apmr.2000.717010.1053/apmr.2000.7170 ↗
5. 10.2519/jospt.2004.34.1.2110.2519/jospt.2004.34.1.21 ↗
6. 10.1007/s00421-011-2133-710.1007/s00421-011-2133-7 ↗
7. 10.1016/j.jcrc.2013.02.01010.1016/j.jcrc.2013.02.010 ↗
8. 10.1016/j.jelekin.2019.02.00710.1016/j.jelekin.2019.02.007 ↗
9. Pavlović R, Trkulja-Petković D, Dragutinović S. Electro-muscle stimulation — the application in practice. A Kin Int Sci J Kin. 2016; 10: 49–55.
10. 10.1016/j.eurger.2015.11.01010.1016/j.eurger.2015.11.010 ↗
11. 10.1080/0040516080259747910.1080/00405160802597479 ↗
12. 10.1177/0040517521105194910.1177/00405175211051949 ↗
13. 10.1177/0040517521104893610.1177/00405175211048936 ↗
14. 10.1002/adma.20140063310.1002/adma.201400633 ↗
15. 10.1177/004051751985876810.1177/0040517519858768 ↗
16. 10.1177/0040517522110820810.1177/00405175221108208 ↗
17. 10.1080/02564602.2022.203081510.1080/02564602.2022.2030815 ↗
18. 10.3390/mti802000710.3390/mti8020007 ↗
19. 10.3390/jcm909290210.3390/jcm9092902 ↗
20. Doucet BM, Lam A, Griffin L. Neuromuscular electrical stimulation for skeletal muscle function. Yale J Biol Med 2012; 85(2): 201.
21. 10.6061/clinics/2019/e133410.6061/clinics/2019/e1334 ↗
22. 10.1177/205566831985434010.1177/2055668319854340 ↗
23. 10.1080/17483107.2019.166897410.1080/17483107.2019.1668974 ↗
24. 10.1177/0040517521105194910.1177/00405175211051949 ↗
25. 10.1186/s12938-024-01246-810.1186/s12938-024-01246-8 ↗
26. 10.4068/cmj.2021.57.1.7610.4068/cmj.2021.57.1.76 ↗
27. 10.3390/bioengineering1006068010.3390/bioengineering10060680 ↗
28. 10.1039/D2NR06008F10.1039/D2NR06008F ↗
29. Lindqvist R. Kinetic Garment Construction: Remarks on the Foundations of Pattern Cutting. PhD Thesis University of Borås 2015.
30. Knibbe J Freire R Koelle M Strohmeier P. Skill-sleeves: designing electrode garments for wearability. In: Proceedings of the 15th International Conference on Tangible Embedded and Embodied Interaction. New York: ACM Press 2021. Article 14. DOI: 10.1145/3430524.344065210.1145/3430524.3440652 ↗
31. 10.12691/ajssm-2-4-810.12691/ajssm-2-4-8 ↗
32. Stegeman D Hermens H. Standards for Surface Electromyography: The European Project Surface EMG for Non-Invasive Assessment of Muscles (SENIAM). Enschede: Roessingh Research and Development 2007; pp. 8–12.
33. Edwards RH. Human muscle function and fatigue. In: Ciba Foundation Symposium 82‐Human Muscle Fatigue: Physiological Mechanisms. Chichester UK: John Wiley & Sons Ltd 1981; p. 1–18.10.1002/9780470715420.ch1 ↗
34. Enoka RM. Neuromechanics of Human Movement. Champaign, IL: Human Kinetics, 2008.
35. 10.1519/00124278-200505000-0003310.1519/00124278-200505000-00033 ↗
36. 10.1519/JSC.000000000000435910.1519/JSC.0000000000004359 ↗
37. 10.1123/jsr.2021-026410.1123/jsr.2021-0264 ↗
38. 10.1519/JSC.0b013e31823f2cd110.1519/JSC.0b013e31823f2cd1 ↗
39. 10.1371/journal.pone.012688810.1371/journal.pone.0126888 ↗
40. 10.3390/jfmk901001010.3390/jfmk9010010 ↗
41. Gueli AM Ferrante M Trigona C Failla A Fiore M. Measurements of wearable noninvasive transducers for sport performance improvement. In: 2019 IEEE International Symposium on Measurements & Networking (M&N). IEEE 2019; pp. 1–5.10.1109/IWMN.2019.8805026 ↗
42. 10.1016/j.mtbio.2023.10056510.1016/j.mtbio.2023.100565 ↗
43. 10.1016/j.clinph.2014.10.21810.1016/j.clinph.2014.10.218 ↗