Thermal and moisture control performance of different mastectomy bras and external breast prostheses
Source abstract
Abstract
This paper introduces a project involving a thermoregulation performance experiment design to evaluate the different responses of research subjects to a range of mastectomy bras and external breast prostheses. A set of newly designed heat-reduction mastectomy bras and prostheses were mix-matched with a set of conventional mastectomy bras and prostheses for the experiment. Four combinations of mastectomy bras and external breast prostheses were used: (a) Com A: conventional mastectomy bra and conventional prosthesis; (b) Com B: conventional mastectomy bra and heat-reduction prosthesis; (c) Com C: heat-reduction mastectomy bra and conventional prosthesis; and (d) Com D: heat-reduction mastectomy bra and heat-reduction prosthesis. Nine healthy male subjects (mean age: 31.9 ± 5.9 y and mean under-bust circumference: 35.3 ± 2.8 in) participated in this study in lieu of women who had undergone surgery for double mastectomy and were too self-conscious to expose their scars for sensor attachment. Eight sets of temperature and humidity sensors were placed between the surface of the skin and the prostheses and bra to measure the changes in both temperature and humidity data in a microclimate environment while the participants performed physical activity. The results showed that Com D demonstrated better thermal and moisture control, resulting in lower body temperature and lower humidity increment throughout the entire experiment. The study proved that the heat-reduction mastectomy bra and external breast prosthesis were effective in releasing the trapped heat and perspiration underneath the bra, and thus would provide a positive impact on clothing comfort and wearing experience for women who had undergone mastectomies.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Laser Applications in Dentistry and Medicine · Infrared Thermography in Medicine
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Textiles and Clothing, The Hong Kong Polytechnic University, China
School of System Design and Intelligent Manufacturing, Southern University of Science and Technology, China
Dr Stephen Hui Research Centre for Physical Recreation and Wellness, Hong Kong Baptist University, China
Funding
the General Research Fund of the Hong Kong Research Grant Council · the Hong Kong Polytechnic University
References (33)
Show source-provided references
1. 10.1158/1055-9965.EPI-15-057810.1158/1055-9965.EPI-15-0578 ↗
2. 10.1002/ijc.2921010.1002/ijc.29210 ↗
3. World Health Organization. Breast cancer: prevention and control, http://www.who.int/cancer/detection/breastcancer/en/ (accessed 13 April 2018).
4. 10.3322/caac.2133810.3322/caac.21338 ↗
5. 10.3322/caac.2133210.3322/caac.21332 ↗
6. Hong Kong Cancer Registry. Cancer facts, https://www3.ha.org.hk/cancereg/facts.html (2016, accessed 19 June 2019).
7. Hong Kong Breast Cancer Foundation. Hong Kong Breast Cancer Registry Report No. 10, Hong Kong Breast Cancer Foundation, 2018.
8. Leung TF. Mastectomy bra and prosthesis design innovation for Hong Kong mastectomy patients . Dissertation, The Hong Kong Polytechnic University, Hong Kong, 2017.
9. 10.1080/17543266.2016.125028910.1080/17543266.2016.1250289 ↗
10. 10.1111/j.1365-2354.2008.00942.x10.1111/j.1365-2354.2008.00942.x ↗
11. 10.1093/es/1.3.56510.1093/es/1.3.565 ↗
12. Amoena. Breast form evolution, http://www.amoena.com/us-en/about-us/breast-form-evolution/ (accessed 12 February 2019).
13. Silique. Silique designed for a new you, http://www.siliquebreastforms.com/index.php (accessed 12 February 2019).
14. 10.1080/00140139.2017.130663010.1080/00140139.2017.1306630 ↗
15. 10.1093/annweh/wxx05510.1093/annweh/wxx055 ↗
16. 10.1177/004051751559177310.1177/0040517515591773 ↗
17. 10.1016/j.mtcomm.2015.11.00510.1016/j.mtcomm.2015.11.005 ↗
18. Jiao J. Effects of clothing on running physiology and performance in a hot condition . Dissertation, The Hong Kong Polytechnic University, Hong Kong, 2014.
19. 10.1080/17461391.2014.92891410.1080/17461391.2014.928914 ↗
20. Kaplan S · Indian J Fibre Text · 2012 · 37 · 46
21. 10.1007/s12221-012-0647-110.1007/s12221-012-0647-1 ↗
22. 10.1080/02640414.2010.52194410.1080/02640414.2010.521944 ↗
23. 10.3993/jfbi0920090610.3993/jfbi09200906 ↗
24. 10.1080/0014013950892516010.1080/00140139508925160 ↗
25. 10.15314/TJSE.20142811210.15314/TJSE.201428112 ↗
26. 10.1016/S1440-2440(99)80193-510.1016/S1440-2440(99)80193-5 ↗
27. 10.1177/004051751246428910.1177/0040517512464289 ↗
28. 10.1080/0014013080270790710.1080/00140130802707907 ↗
29. Wong ASW, Li Y and Newton E. Mathematical simulation of human psychological perception of moisture sensation. In: Zeng X, Li Y, Ruan D, et al. (eds) Computation textile . Berlin, Heidelberg: Springer, 2007, pp.265–273.10.1007/978-3-540-70658-8_17 ↗
30. Li Y · 2006
31. 10.1007/s00421-014-2875-010.1007/s00421-014-2875-0 ↗
32. 10.1016/j.physbeh.2015.07.03710.1016/j.physbeh.2015.07.037 ↗
33. Shin K. Patternmaking for underwear design . 2nd ed. CreateSpace, 2015.