Are running socks beneficial for comfort? The role of the sock and sock fiber type on shoe microclimate and subjective evaluations
Source abstract
Abstract
This study evaluated the effect of socks (different in fiber type) and the effect of not wearing a sock on perceptions of thermal comfort in relation to changes in foot skin temperature and shoe microclimate (temperature and humidity) during rest and exercise. Ten females completed five trials on separate occasions. Four socks (cotton, wool, polyester, Coolmax) and no sock were evaluated. Trials were conducted at 23°C, 50% relative humidity and consisted of rest (10 min seated), treadmill running (40 min, 7.5 km·h −1 ) and recovery (15 min seated). Foot skin temperature and shoe microclimate were measured at seven sites on the right foot. Foot skin hydration was measured at nine foot sites. Perceptual responses were recorded. Foot thermo-physiological and foot perceptual responses were similar for all sock conditions ( p > 0.05). Similar foot thermo-physiological responses were also observed between the sock and no sock conditions ( p > 0.05). Interestingly, however, not wearing a sock resulted in greater perceptions of foot wetness, stickiness and discomfort ( p < 0.05). As tactile interactions caused by foot movement within the shoe are strong predictors of foot wetness perception (a key contributor to wear discomfort), socks are important in reducing the tactile cues generated. The sock is therefore an important area for development and relevant for overall improvements in footwear comfort.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Thermoregulation and physiological responses · Textile materials and evaluations · Exercise and Physiological Responses
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Environmental Ergonomics Research Centre, Loughborough School of Design and Creative Arts, Loughborough University, UK
Funding
adidas FUTURE team · Loughborough University
References (37)
Show source-provided references
1. 10.3810/psm.2004.05.30410.3810/psm.2004.05.304 ↗
2. 10.1038/jid.1966.16910.1038/jid.1966.169 ↗
3. 10.1016/j.apergo.2012.11.00710.1016/j.apergo.2012.11.007 ↗
4. 10.1177/004051751350736210.1177/0040517513507362 ↗
5. 10.1016/j.apergo.2019.01.01010.1016/j.apergo.2019.01.010 ↗
6. 10.33697/ajur.2011.01910.33697/ajur.2011.019 ↗
7. 10.1177/004051751036940910.1177/0040517510369409 ↗
8. 10.1080/0014013041233129088010.1080/00140130412331290880 ↗
9. 10.1893/0005-3155-85.1.3010.1893/0005-3155-85.1.30 ↗
10. 10.1177/004051751453002910.1177/0040517514530029 ↗
11. 10.1016/j.ergon.2012.01.00110.1016/j.ergon.2012.01.001 ↗
12. 10.7547/87507315-80-2-6310.7547/87507315-80-2-63 ↗
13. 10.1093/milmed/161.10.59410.1093/milmed/161.10.594 ↗
14. 10.1007/s00421-010-1744-810.1007/s00421-010-1744-8 ↗
15. 10.1152/jappl.1964.19.3.53110.1152/jappl.1964.19.3.531 ↗
16. 10.1111/j.1600-0846.2004.00050.x10.1111/j.1600-0846.2004.00050.x ↗
17. 10.1152/japplphysiol.00872.201710.1152/japplphysiol.00872.2017 ↗
18. 10.1016/j.wear.2010.01.01010.1016/j.wear.2010.01.010 ↗
19. 10.1177/004051751246169810.1177/0040517512461698 ↗
20. Bogerd CP · Ann Occup Hyg · 2011 · 55 · 510
21. Bogerd CP · Ann Occup Hyg · 2012 · 56 · 481
22. 10.1201/b1675010.1201/b16750 ↗
23. ISO 10551. Ergonomics of the thermal environment—assessment of the influence of the thermal environment using subjective judgement scales. Geneva: International Standard, 2019.
24. 10.1177/004051751771690510.1177/0040517517716905 ↗
25. ISO 15831. Clothing—Physiological effects—Measurement of thermal insulation by means of a thermal manikin. 2004.
26. 10.1152/jn.00141.201510.1152/jn.00141.2015 ↗
27. 10.1016/j.apergo.2018.05.01410.1016/j.apergo.2018.05.014 ↗
28. 10.1080/00140139.2019.165718510.1080/00140139.2019.1657185 ↗
29. 10.1007/s00421-014-2875-010.1007/s00421-014-2875-0 ↗
30. 10.1016/j.physbeh.2015.08.03210.1016/j.physbeh.2015.08.032 ↗
31. 10.1016/j.jtherbio.2012.06.00310.1016/j.jtherbio.2012.06.003 ↗
32. 10.1016/0031-9384(74)90269-810.1016/0031-9384(74)90269-8 ↗
33. 10.1177/004051751667112710.1177/0040517516671127 ↗
34. 10.1177/00405175040740111010.1177/004051750407401110 ↗
35. 10.1080/00140139.2011.58295810.1080/00140139.2011.582958 ↗
36. 10.1177/00405175510210010710.1177/004051755102100107 ↗
37. 10.1177/00405175980680040610.1177/004051759806800406 ↗