Evaluation of Overall and Local Ventilation in Diapers
Source abstract
Abstract
A device to evaluate the distribution of the ventilation in diapers by using a tracer gas method (steady state method) was developed to investigate the effect of the design- and material-factor of diapers on heat and water vapor transfer by ventilation. This device can also evaluate the quantitative local microclimate ventilation rate during rest or walking between the interior of the diaper and the ambient atmosphere. Using forced ventilation, it was shown that the devices’ measurement captured the actual ventilation in the diapers. For the overall ventilation values it was found that the air permeability of the diaper fabric affected the ventilation but did not dominate it. It means the ventilation was affected not only by the air permeability but also by the construction and design of clothing. Leg movement caused about 20% increase of ventilation compared to the static condition. The ventilation of the pants design diapers were less affected by the movement. For the local ventilation values, the ventilation of the front upper site contributed heavily to the overall ventilation. The repeatability of the microclimate ventilation values measured by the steady state method obtained in our present study was better than that of the transient method reported in our earlier paper. It was demonstrated that the device allowed the evaluation of diaper design for the purpose of improving the microclimate in the diaper.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Neonatal skin health care · Pressure Ulcer Prevention and Management · Thermoregulation and physiological responses
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Education and Human Sciences, Yokohama National University, Japan,
Department of Ergonomics (Human Sciences), Loughborough University, United Kingdom
References (21)
Show source-provided references
1. 2008
2. 2008
3. Tezuka, K. · 2007
4. Crockford, G.W. · J. Indust. Med · 1972 · 29 · 378
5. 10.1016/0003-6870(78)90079-010.1016/0003-6870(78)90079-0 ↗
6. Berglund, L.G. · TAPPI J. · 1997 · 80 · 173
7. 10.1108/0955622991029167710.1108/09556229910291677 ↗
8. 10.1080/0014013900892709410.1080/00140139008927094 ↗
9. 10.1080/0014013900892530810.1080/00140139008925308 ↗
10. Lotens W.A., Havenith, G. Ventilation of rainwear determined by a trace gas method. In: Environmental Ergonomics. Mekjavics, Bannister, Morrison Eds. Taylor and Francis, Philadelphia, 1988, pp. 162-175.
11. Havenith, G. · EPSRC Report on Project GR/N10509/01 · 2000
12. 10.1080/0014013090352815210.1080/00140130903528152 ↗
13. 10.1016/S1572-347X(05)80054-010.1016/S1572-347X(05)80054-0 ↗
14. 10.1108/0955622061066847310.1108/09556220610668473 ↗
15. 10.2115/fiber.56.52410.2115/fiber.56.524 ↗
16. 10.2115/fiber.59.2210.2115/fiber.59.22 ↗
17. Satsumoto, Y. and Takeuchi, M. The effect of bellows action on heat transfer in clothing system. The effect of the number and the depth of opening, Proceedings of the third international conference on human-environment system, ICHES’05, in Tokyo, Japan, 12 ( 2005).
18. 10.1115/1.147152410.1115/1.1471524 ↗
19. 10.1016/j.ijheatmasstransfer.2005.03.00110.1016/j.ijheatmasstransfer.2005.03.001 ↗
20. 10.1115/1.294424510.1115/1.2944245 ↗
21. Satsumoto, Y. · HES32 in Cheju · 2008