journal article·2021-11

Influence of incident energy on the properties of arc rated para-aramid fabric

Xia Li, Qilong Sun, Shuo Wang, Hong Tang

Textile Research Journal· Volume 91· Issue 21-22
Publisher page

Abstract

To study the protection mechanism of para-aramid fabrics under an electric arc, the structural composition, surface morphology, and thermal properties of an untreated para-aramid fabric and that treated with different incident energy arcs were compared. The intensity of the N-H peak of the para-aramid cellulose amide decreased with increasing exposed arc energy. Moreover, intensities of the C=O peak of the amide bond type I carbonyl and the C-H deformation vibration absorption peak originating from the benzene ring gradually weakened. In contrast, the carbon content of the fabric increased. In the arc deflagration process, the fiber broke and then carbonized and embrittled. With an arc energy of 30.9 cal/cm 2 , the carbonization degree of the front surface of the fabric increased and was highest at the float line. The initial combustion temperature remained unchanged, and the mass residual quantity gradually increased with increasing arc energy exposed to the fabric. The above results suggest that para-aramid fabric can protect the end user in an arc by carbonization, offering effective assistance in the research and development of personal protective equipment for arc flashes.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electrical Fault Detection and Protection · Risk and Safety Analysis · Combustion and Detonation Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Textiles and Clothing, Nantong University, China

National & Local Joint Engineering Research Center of Technical Fiber Composites for Safety and Protection, Nantong University, China

School of Translation Studies, Jinan University, China

References (19)

Show source-provided references
1. Fedoroff, Basil T (eds). Encyclopedia of explosives and related items . Dover, NJ: Picatinny Arsenal, 1960–1983.
2. 10.1109/TIA.2013.228823910.1109/TIA.2013.2288239 ↗
3. Laverty G. · Power Saf Technol · 2008 · 10 · 64
4. 10.1109/TIA.2011.215381010.1109/TIA.2011.2153810 ↗
5. 10.1016/j.epsr.2014.05.01110.1016/j.epsr.2014.05.011 ↗
6. Floyd HL, Doan DR, Wu CT, et al . Arc flash hazards and electrical safety program implementation. In: Louie JP (ed.) Industry Applications Conference , Hong Kong, China, 2-6 October 2005, pp.1919-1923. Vol.3, no.54. Piscataway: IEEE Operations Center.10.1109/IAS.2005.1518709 ↗
7. 10.1109/TIA.2004.83079610.1109/TIA.2004.830796 ↗
8. 10.1533/9780857098931.4.54910.1533/9780857098931.4.549 ↗
9. Kondo K, Honshida S, Amano T. Flame retardant adhesive sheet, coverlay film and flexible copper-clad laminate using same . Patent 782074[P], USA, 2010.
10. Song LZ. · Techn Text · 1997 · 06 · 29
11. 10.1002/(SICI)1097-4628(19990124)71:4<565::AID-APP7>3.0.CO;2-P10.1002/(SICI)1097-4628(19990124)71:4<565::AID-APP7>3.0.CO;2-P ↗
12. 10.7209/tanso.1983.15510.7209/tanso.1983.155 ↗
13. Zhang HT. · Shanghai Text Sci Technol · 2012 · 40 · 8
14. 10.1007/s10973-010-1211-010.1007/s10973-010-1211-0 ↗
15. 10.1177/00405175770470011310.1177/004051757704700113 ↗
16. ASTM F1959:1999. Standard test method for determining the arc thermal performance value of materials for clothing.
17. IEEE Std 1584TM:2002. IEEE guide for performing arc-flash hazard calculations.
18. Zhu ZF · J Zhongyuan Univ Technol · 2011 · 22 · 22
19. Chen GQ. · Shandong Text Sci Technol · 2015 · 56 · 49