Polydioxanone weft-knitted intestinal stents: fabrication and mechanics optimization
Source abstract
Abstract
This paper presents the fabrication of polydioxanone weft-knitted stents and the mechanical properties optimization on process parameters. The stents can be used for treatment of intestinal obstruction and stenosis. Patients diagnosed with different phases require different mechanical stents. So, the mechanical properties of stents, radial force and circumferential strength are important for the safety and efficiency of stents. The aim of this paper was to identify the effect of process parameters on the mechanical properties of stents using the statistical modeling method, then propose optimum parameter settings. The intra-abdominal and intra-intestinal pressures of the human intestine were investigated through an intestine physical model; a full factorial experiment was employed to identify the most suitable factors and find the optimum processing parameters according to the two pressures identified. The results showed that optimum stents with radial force in the range of 1.3–2.5 cN/mm and circumferential strength in the range of 20–50 cN/mm could be obtained at a stitch cam setting ranging from 3.2 to 3.4 mm, with fabric tension in the range of 140–160 cN if the yarn tension and yarn linear density were held at 1.2 cN and 150 tex, respectively. The model validation results showed that stents with different mechanical properties could be tailored through the statistical method and proposed model. In conclusion, such stents, and optimization method, may find broad applications clinically.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Intestinal and Peritoneal Adhesions · Abdominal Surgery and Complications · Hernia repair and management
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Hong Kong
Department of Colorectal Surgery, the Sixth Affiliated Hospital (Gastrointestinal Hospital) of Sun Yat-Sen University, China
References (25)
Show source-provided references
1. 10.1111/j.1463-1318.2004.00727.x10.1111/j.1463-1318.2004.00727.x ↗
2. 10.1148/radiology.215.3.r00jn3065910.1148/radiology.215.3.r00jn30659 ↗
3. 10.1046/j.1365-2168.2002.02148.x10.1046/j.1365-2168.2002.02148.x ↗
4. 10.1002/jbm.b.3078610.1002/jbm.b.30786 ↗
5. 10.1007/s00330-009-1662-510.1007/s00330-009-1662-5 ↗
6. 10.1002/jbm.b.3031910.1002/jbm.b.30319 ↗
7. 10.1067/mtc.2002.11850310.1067/mtc.2002.118503 ↗
8. Rejchrt S · Folia Gastroenterol Hepatol · 2009 · 7 · 7
9. 10.1016/j.ijom.2005.04.02710.1016/j.ijom.2005.04.027 ↗
10. 10.3233/THC-2006-144-50610.3233/THC-2006-144-506 ↗
11. 10.1115/1.226438210.1115/1.2264382 ↗
12. 10.1016/j.jbiomech.2008.01.01610.1016/j.jbiomech.2008.01.016 ↗
13. 10.1177/004051750809359410.1177/0040517508093594 ↗
14. Fatkić E · Fibres Textil East Eur · 2011 · 19 · 88
15. 10.1177/00405175000700120110.1177/004051750007001201 ↗
16. Nakarani M · Acta Pharmaceutica Sciencia · 2010 · 52 · 400
17. 10.1007/s00449990016410.1007/s004499900164 ↗
18. Kim Y, Lee G, Park S, et al. Pressure monitoring system in gastro-intestinal tract. In: Proceedings of the IEEE international conference on robot and automat , Barcelona, 2005, pp.1321–1326.
19. Martinez-de-Juan J · Proc IEEE EMBS Hong Kong · 1998 · 3 · 1505
20. 10.1016/j.bspc.2009.03.00710.1016/j.bspc.2009.03.007 ↗
21. 10.1177/08850666000150040310.1177/088506660001500403 ↗
22. 10.1080/0040500090336359710.1080/00405000903363597 ↗
23. 10.1163/1568562026044971410.1163/15685620260449714 ↗
24. Spencer DJ · 2001
25. Montgomery DC and Myers RH. Response surface methodology: Process and product optimization using designed experiments . 2nd ed. John Wiley & Sons: Hoboken, New Jersey, 2002.