journal article·2019-09Open access

Effect of perspired moisture and material properties on evaporative cooling and thermal protection of the clothed human body exposed to radiant heat

Manhao Guan, Agnes Psikuta, Martin Camenzind, Jun Li, Sumit Mandal, René Michel Rossi, Simon Annaheim

Textile Research Journal· Volume 89· Issue 18

Abstract

Perspired moisture plays a crucial role in the thermal physiology and protection of the human body wearing thermal protective clothing. Until now, the role of continuous sweating on heat transfer, when simultaneously considering internal and external heat sources, has not been well-investigated. To bridge this gap, a sweating torso manikin with 12 thermal protective fabric systems and a radiant heat panel were applied to mimic firefighting. The results demonstrated how the effect of radiant heat on heat dissipation interacted with amount of perspired moisture and material properties. A dual effect of perspired moisture was demonstrated. For hydrophilic materials, sweating induced evaporative cooling but also increased radiant heat gain. For hydrophilic station uniforms, the increment of radiant heat gain due to perspired moisture was about 11% of the increase of heat dissipation. On the other hand, perspired moisture can increase evaporative cooling and decrease radiant heat gain for hydrophobic materials. In addition to fabric thermal resistance ( R ct ) and evaporative resistance ( R et ), material hydrophilicity and hydrophobicity, emissivity and thickness are important when assessing metabolic heat dissipation and radiant heat gain with profuse sweating under radiant heat. The results provide experimental evidence that R ct and R et , the general indicators of the clothing thermo-physiological effect, have limitations in characterizing thermal comfort and heat strain during active liquid sweating in radiant heat. This paper offers a more complete insight into clothing thermal characteristics and human thermal behaviors under radiant heat, contributing to the accurate evaluation of thermal stress for occupational and general individuals.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Textile materials and evaluations · Thermoregulation and physiological responses · Skin Protection and Aging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Fashion and Design, Donghua University, China

Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Biomimetic Membranes and Textiles, St. Gallen, Switzerland

Key Laboratory of Clothing Design and Technology, College of Fashion and Design, Donghua University, Ministry of Education, China

Tongji University Shanghai Institute of Design and Innovation, China

References (49)

Show source-provided references
1. Pan N. Sweat management for military applications. In: Wilusz E (ed.) Military textiles . Cambridge: Woodhead Publishing, 2008, pp.137–157.10.1533/9781845694517.1.137 ↗
2. 10.1080/001401303100012196810.1080/0014013031000121968 ↗
3. ISO 11092:2014. Textiles — physiological effects — measurement of thermal and water-vapour resistance under steady-state conditions (sweating guarded-hotplate test).
4. 10.1080/10803548.2010.1107684210.1080/10803548.2010.11076842 ↗
5. 10.1177/004051751559692610.1177/0040517515596926 ↗
6. 10.1108/IJCST-05-2014-006410.1108/IJCST-05-2014-0064 ↗
7. 10.1177/004051751038010810.1177/0040517510380108 ↗
8. 10.1177/00405175000700070210.1177/004051750007000702 ↗
9. Song G-W, Mandal S and Rossi RM. Performance evaluation of thermal protective clothing. Thermal protective clothing for firefighters . Cambridge: Woodhead Publishing, 2017, pp.57–144.10.1016/B978-0-08-101285-7.00005-8 ↗
10. ASTM F1868:2017. Standard test method for thermal and evaporative resistance of clothing materials using a sweating hot plate.
11. 10.1177/004051751558826910.1177/0040517515588269 ↗
12. 10.1016/j.polymertesting.2006.03.00210.1016/j.polymertesting.2006.03.002 ↗
13. ASTM F2370:2016. Standard test method for measuring the evaporative resistance of clothing using a sweating manikin.
14. ASTM F1291:2016. Standard test method for measuring the thermal insulation of clothing using a heated manikin.
15. ISO 9920:2007. Ergonomics of the thermal environment -estimation of thermal insulation and water vapour resistance of a clothing ensemble.
16. 10.1080/00405000.2014.99592910.1080/00405000.2014.995929 ↗
17. 10.1177/004051751246170710.1177/0040517512461707 ↗
18. 10.1016/j.firesaf.2007.11.00710.1016/j.firesaf.2007.11.007 ↗
19. Mandal S · Ann Occup Hyg · 2014 · 58 · 1065
20. 10.1007/s10694-010-0151-310.1007/s10694-010-0151-3 ↗
21. 10.1177/004051750605394710.1177/0040517506053947 ↗
22. 10.1002/fam.227810.1002/fam.2278 ↗
23. 10.1016/j.jhazmat.2014.05.05610.1016/j.jhazmat.2014.05.056 ↗
24. 10.1177/004051751139894310.1177/0040517511398943 ↗
25. 10.1177/004051750809048410.1177/0040517508090484 ↗
26. 10.1177/07349041860040050210.1177/073490418600400502 ↗
27. 10.1080/10803548.2004.1107661010.1080/10803548.2004.11076610 ↗
28. 10.1007/s12221-012-0549-210.1007/s12221-012-0549-2 ↗
29. 10.1007/s12221-012-0647-110.1007/s12221-012-0647-1 ↗
30. Rossi RM and Zimmerli T. Influence of humidity on the radiant, convective and contact heat transmission through protective clothing materials. In: Johnson J and Mansdorf S (eds) Performance of protective clothing: fifth volume . West Conshohocken, PA: ASTM International, 1996, pp.269–280.10.1520/STP14074S ↗
31. Stull JO. Comparative thermal insulative performance of reinforced knee areas of firefighter protective clothing. In: Performance of protective clothing: issues and priorities for the 21st century: seventh volume . West Conshohocken, PA: ASTM International, 2000, pp.312–328.10.1520/STP14454S ↗
32. Mäkinen H, Smolander J and Vuorinen H. Simulation of the effect of moisture content in underwear and on the skin surface on steam burns of fire fighters. In: S Mansdorf, R Sager and A Neilsen (eds.) performance of protective clothing: second symposium , Tampa, FI, 19 January-21 January 1987, paper no. STP989-EB, pp. 415–421. Philadelphia, PA: ASTM International. 1988.10.1520/STP26309S ↗
33. ISO 7933:2004. Ergonomics of the thermal environment – analytical determination and interpretation of heat stress using calculation of the predicted heat strain.
34. 10.1080/10803548.2010.1107684310.1080/10803548.2010.11076843 ↗
35. ISO3801:1977. Textiles – woven fabrics – determination of mass per unit length and mass per unit area.
36. ISO5084:1996. Textiles – determination of thickness of textiles and textile products.
37. ISO18640-1:2018. Protective clothing for firefighters — physiological impact — Part 1: measurement of coupled heat and moisture transfer with the sweating torso.
38. ISO18640-2:2018. Protective clothing for firefighters — physiological impact — Part 2: determination of physiological heat load caused by protective clothing worn by firefighters.
39. 10.1108/IJCST-02-2014-002010.1108/IJCST-02-2014-0020 ↗
40. Zimmerli T and Weder MS. Protection and comfort—a sweating torso for the simultaneous measurement of protective and comfort properties of PPE. Performance of protective clothing: sixth volume . West Conshohocken, PA: ASTM International, 1997, pp.271–280.10.1520/STP19909S ↗
41. Wang F-M, Havenith G, Mayor TS, et al. (eds). Clothing real evaporative resistance determined by means of a sweating thermal manikin: a new round-robin study. In: M Varheenmaa (ed.) 10th manikin and modelling meeting (10i3m) , Tampere, Finland, 7–9 September 2014, paper no. 145. Tampere, Finland: Tampere University of Technology. Department of Materials Science.
42. Song G-W, Mandal S and Rossi RM. Modeling and its implications on performance of thermal protective clothing. Thermal protective clothing for firefighters . Cambridge: Woodhead Publishing, 2017, pp.145–161.10.1016/B978-0-08-101285-7.00006-X ↗
43. ANSI/ASHRAE Standard 55, Thermal environmental conditions for human occupancy. 2004.
44. 10.1007/s00421005045010.1007/s004210050450 ↗
45. 10.1007/s00484-016-1217-910.1007/s00484-016-1217-9 ↗
46. 10.1177/00405175050750011110.1177/004051750507500111 ↗
47. 10.1177/004051751455958210.1177/0040517514559582 ↗
48. 10.1177/004051751455145810.1177/0040517514551458 ↗
49. 10.1007/s00484-015-0978-x10.1007/s00484-015-0978-x ↗