Moisture transfer of the clothing–human body system during continuous sweating under radiant heat
Source abstract
Abstract
Mass transfer due to perspired moisture in a clothing system is critical for the understanding of thermo-physiology and thermal protection of a clothed body. Previous studies usually investigated moisture transfer without considering the effect of liquid sweating or external heat hazards. To understand the mechanisms of sweat evaporation, accumulation and dripping with continuous sweating under radiant heat, a multi-phase experiment was designed with a sweating Torso. The concept of clothed wettedness was proposed to understand sweat evaporation of the clothed body. Results showed that the evaporation rate of the clothed body increased with increasing perspiration rate and the rate increase can be explained by the material properties (e.g., material composition, hydrophilicity and evaporative resistance ([Formula: see text])), which affected the sweat accumulation ability. Results also demonstrated a dual relationship of [Formula: see text] with the evaporation rate of the clothed body. Firstly, the evaporation rate was increased for greater [Formula: see text] due to the higher moisture accumulation. Secondly, when [Formula: see text] exceeded a certain value, the evaporation rate decreased with greater [Formula: see text] due to the reduction in the mass transfer coefficient. For radiant heat exposure, evaporated sweat may condense on the skin surface, decreasing the evaporation rate and increasing the dripping rate. The sweat transfer process was also investigated in detail by the combined analysis of the sweat transfer rate and the evaporative cooling efficiency. This study provides insights into how continuous liquid sweat transfers and evaporates in the clothed body and its interaction with clothing material and environment radiant heat, contributing to the understanding of thermo-physiological burden and thermal protection of the clothed body with intensive activities.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Textile materials and evaluations · Thermoregulation and physiological responses · Skin Protection and Aging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Fashion and Design, Donghua University, China
Laboratory for Biomimetic Membranes and Textiles, Swiss Federal Laboratories for Materials Science and Technology, Empa, Switzerland
Key Laboratory of Clothing Design and Technology, Donghua University, Ministry of Education, China
Shanghai Institute of Design and Innovation, Tongji University, China
References (51)
Show source-provided references
1. 10.1016/j.expthermflusci.2012.12.01310.1016/j.expthermflusci.2012.12.013 ↗
2. Mäkinen H, Smolander J and Vuorinen H. Simulation of the effect of moisture content in underwear and on the skin surface on steam burns of fire fighters. In: performance of protective clothing: second symposium (eds. SZ Mansdorf, R Sager and AP Nielse), Tampa, Florida, 19–21 January 1987, paper no. 7, pp. 415–421. Philadelphia, PA: ASTM International.10.1520/STP26309S ↗
3. 10.1177/004051750605394710.1177/0040517506053947 ↗
4. 10.1016/0894-1777(94)90035-310.1016/0894-1777(94)90035-3 ↗
5. 10.1016/j.ijheatmasstransfer.2003.10.03310.1016/j.ijheatmasstransfer.2003.10.033 ↗
6. Berglund LG · J Appl Physiol Respir Environ Exerc Physiol · 1977 · 42 · 767
7. Candas V · J Appl Physiol Respir Environ Exerc Physiol · 1979 · 46 · 522
8. 10.1152/jappl.1972.33.3.33110.1152/jappl.1972.33.3.331 ↗
9. 10.1152/jappl.1974.36.3.31310.1152/jappl.1974.36.3.313 ↗
10. 10.1152/jappl.1963.18.4.80810.1152/jappl.1963.18.4.808 ↗
11. Nagata H · J Hum Ergol (Tokyo) · 1978 · 7 · 169
12. 10.1007/BF0042295610.1007/BF00422956 ↗
13. 10.1080/0014013960896445310.1080/00140139608964453 ↗
14. Frye AJ · J Appl Physiol Respir Environ Exerc Physiol · 1983 · 54 · 972
15. Candas V · J Appl Physiol Respir Environ Exerc Physiol · 1979 · 47 · 1194
16. Givoni B. Elements of heat exchanges between man and his thermal environment. In: Givoni B (ed.), Man, climate and architecture . London: Applied Science Publishers, 1981.
17. Hettinger T, Eissing G, Hertting R, et al. Belastung und Beanspruchung durch das Tragen persönlicher Schutzausrüstungen, BAU (Hrsg.). Forschungsbericht Nr.392, Wirtschaftsverlag NW, Bremerhaven, 1985.
18. 10.1080/0014013820892495510.1080/00140138208924955 ↗
19. Vogt JJ · 1981 · 99
20. ASTM F1868-17:2017. Standard test method for thermal and evaporative resistance of clothing materials using a sweating hot plate.
21. ASTM F2370-16:2016. Standard test method for measuring the evaporative resistance of clothing using a sweating manikin.
22. ISO 11092:2014. Textiles – physiological effects – measurement of thermal and water- vapour resistance under steady-state conditions (sweating guarded-hotplate test).
23. ISO 9920:2007. Ergonomics of the thermal environment -estimation of thermal insulation and water vapour resistance of a clothing ensemble.
24. ISO 7933:2004. Ergonomics of the thermal environment – analytical determination and interpretation of heat stress using calculation of the predicted heat strain.
25. 10.1152/japplphysiol.00612.200710.1152/japplphysiol.00612.2007 ↗
26. Nish Y · Ashrae Trans · 1970 · 76 · 137
27. 10.1007/s00421-004-1115-410.1007/s00421-004-1115-4 ↗
28. 10.1111/sms.1211710.1111/sms.12117 ↗
29. 10.1152/japplphysiol.01271.201210.1152/japplphysiol.01271.2012 ↗
30. 10.1007/s00484005007310.1007/s004840050073 ↗
31. 10.1007/s00421005045010.1007/s004210050450 ↗
32. 10.1080/10803548.2010.1107684210.1080/10803548.2010.11076842 ↗
33. 10.1177/004051750809048410.1177/0040517508090484 ↗
34. 10.1016/j.measurement.2012.11.00910.1016/j.measurement.2012.11.009 ↗
35. Mosher H · J Biol Chem · 1933 · 99 · 78110.1016/S0021-9258(18)76026-2 ↗
36. ISO18640-1:2018. Protective clothing for firefighters – physiological impact – part 1: measurement of coupled heat and moisture transfer with the sweating torso.
37. ISO18640-2:2018. Protective clothing for firefighters – physiological impact – part 2: determination of physiological heat load caused by protective clothing worn by firefighters.
38. 10.1108/IJCST-02-2014-002010.1108/IJCST-02-2014-0020 ↗
39. Zimmerli T and Weder MS. Protection and comfort—a sweating torso for the simultaneous measurement of protective and comfort properties of PPE. In: Stull JO and Schwope AD (eds) Performance of protective clothing: sixth volume . West Conshohocken, PA: ASTM International, 1997, pp.271–280.10.1520/STP19909S ↗
40. ISO 5084:1966. Textiles – determination of thickness of textiles and textile products.
41. ISO 3801:1977. Textiles – woven fabrics – determination of mass per unit length and mass per unit area.
42. ANSI/ASHRAE Standard 55-2017:2004. Thermal environmental conditions for human occupancy.
43. Song G, Mandal S and Rossi RM. Fires and thermal environments. In: Song G, Mandal S and Rossi RM (eds) Thermal protective clothing for firefighters . Cambridge: Woodhead Publishing, 2017, p.8.
44. Wang F, Havenith G, Mayor TS, et al. Clothing real evaporative resistance determined by means of a sweating thermal manikin: a new round-robin study. In: Proceedings of Ambience 14&10i3m: Scientific Conference for Smart and Functional Textiles, Well-Being, Thermal Comfort in Clothing, Design, Thermal Manikins and Modellin (ed. Varheenmaa M), Tampere, Finland, 7–9 September 2014, paper no. 7, pp. 1–7.
45. 10.1007/s00421-008-0966-510.1007/s00421-008-0966-5 ↗
46. Parsons KC and Ken P. Human thermal environments: the effects of hot, moderate, and cold environments on human health, comfort, and performance . Boca Raton, FL: CRC Press, Taylor & Francis Group, 2014.10.1201/b16750 ↗
47. 10.1152/jappl.1976.41.5.77710.1152/jappl.1976.41.5.777 ↗
48. Li K and RN Horne. Comparison of methods to calculate relative permeability from capillary pressure inconsolidated water-wet porous media. Water Resour Res 2006; 42: W06405. DOI: 10.1029/2005WR004482.10.1029/2005WR004482 ↗
49. Guan M · Text Res J
50. Gagge AP. A new physiological variable associated with sensible and insensible perspiration. Am J Physiol 1937; 120: 277–287.10.1152/ajplegacy.1937.120.2.277 ↗