Fiber Length Measurement by Image Processing
Source abstract
Abstract
To act as an alternative to existing systems, image-based fiber length measurements must yield precise results in a reasonable amount of processing time. To be used as a calibration device for current systems, the processing time becomes less important than accuracy and precision. Here, we report on the accuracy and precision of image processing applications compared with existing methods of HVI, AFIS, and hand measurements. Further, we propose preferred system parameters for these two possible applications of the technology.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Industrial Vision Systems and Defect Detection
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Textile Engineering, Chemistry and Science, College of Textiles, North Carolina State University, Raleigh, North Carolina 27695, U.S.A.
Department of Electrical Engineering, North Carolina State University, Raleigh, North Carolina 27695, U.S.A.
References (5)
Show source-provided references
1. 1. Cui, X., Calamari, T. A., Robert, K., and Krowicki, R., An Investigation of Cotton Fiber Lengths Measured by HVI and AFIS, in “Tenth EFS Research Forum Proceedings,” 1997, pp. 115-124.
2. 10.1016/S0734-189X(87)80145-710.1016/S0734-189X(87)80145-7 ↗
3. 10.1016/S0146-664X(79)80041-610.1016/S0146-664X(79)80041-6 ↗
4. 4. Riley, C. R., and Chu, Y. T., HVI Short Fiber Measurements, in “Proc. Seventh Annual EFS Research Forum,” 1994, pp. 303-321.
5. 10.1177/00405175910610020910.1177/004051759106100209 ↗