Properties of Electrospun Polyacrylonitrile Membranes and Chemically-activated Carbon Nanofibers
Source abstract
Abstract
Electrospinning was used to make activated carbon nanofibers with polyacrylonitrile (PAN) as the precursor. The applied voltage was found to be more influential on electrospun PAN fiber diameters than the flow rate and needle tip-collector distance. Tensile load and tear strength of electrospun PAN membranes increased with thickness, accompanied with a decrease in air permeability; however, burst strength was not significantly influenced by the thickness. Electrospun PAN nanofiber membranes were stabilized in air and then activated at 800°C with KOH as the activating agent to make activated carbon nanofibers. Stabilized PAN membranes showed different breaking behaviors from those before stabilization. The maximum tensile stress of the stabilized PAN membranes from different concentrations was affected differently by the stabilization process. The resulting activated carbon nanofibers had no C ≡ N bond. The activation process generated micropores which contributed to a large surface area of 936.2 m 2 /g and a micropore volume of 0.59 cc/g. Pore size distributions of electrospun PAN and activated carbon nanofibers were analyzed based on the Dubinin-Astakhov equation and the generalized Halsey equation. The results showed that activated carbon nanofibers had many more micropores than electrospun PAN, increasing their potential applications in adsorption.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Advanced Sensor and Energy Harvesting Materials · Conducting polymers and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Polymer and Fiber Engineering, Auburn University, Auburn, AL, 36849, USA
Polymer and Fiber Engineering, Auburn University, Auburn, AL, 36849, USA,
References (22)
Show source-provided references
1. Huang, Z.M. · Sci. Technol · 2003 · 63 · 2223
2. 10.1002/app.2429010.1002/app.24290 ↗
3. 10.1002/app.2148110.1002/app.21481 ↗
4. Sutasinpromprae, J. · Int · 2006 · 55 · 825
5. 10.1007/978-1-59259-778-910.1007/978-1-59259-778-9 ↗
6. 10.4028/www.scientific.net/MSF.510-511.75010.4028/www.scientific.net/MSF.510-511.750 ↗
7. Park, S.H. · Met · 2004 · 146 · 207
8. Bansal, R.C. · 1988
9. Kim, C. · Phys. Lett · 2003 · 83 · 1216
10. 10.1149/1.180163110.1149/1.1801631 ↗
11. Chan, K. · Acta · 2004 · 50 · 883
12. 10.4028/www.scientific.net/MSF.449-452.21710.4028/www.scientific.net/MSF.449-452.217 ↗
13. 10.1039/b601546h10.1039/b601546h ↗
14. Lowell, S. · 2006
15. Instruments Q · 1
16. AS1 Win Version 1.51, Operating Manual, Instruments Q, pp. 80-89.
17. 10.1109/TDEI.2006.165797110.1109/TDEI.2006.1657971 ↗
18. 10.1106/1K42-U5RB-H6T7-PU2U10.1106/1K42-U5RB-H6T7-PU2U ↗
19. Adanur, S. · 1995
20. 10.1002/app.2412310.1002/app.24123 ↗
21. 10.1021/bm701225a10.1021/bm701225a ↗
22. Lyklema, J. · 1995