Developing a hybrid cooling vest for combating heat stress in the construction industry
Source abstract
Abstract
Many frontline workers in the Hong Kong construction industry have to perform physically demanding work under hot working conditions, which could reduce work efficiency and time and increase the occurrence of heat cramps, heat exhaustion, and heat stroke. This study aimed to develop a hybrid, new cooling vest to combat heat stress in the construction industry. Following the functional clothing design process, a problem identification was conducted. Preliminary ideas were formed through the analysis of available types, research, a survey, literature review, and brainstorming. The design was refined through the use of desirable phase change material packs, fans with high wind velocity/long duration, and fabrics with thin, vapor-permeable, wind/water/abrasion-resistant properties, and UV protection, as well as clothing ergonomic design that considers fit, mobility, convenience, and safety. The desirable thermal functional performance in the new cooling vest was previewed through a computer-aided design platform S-smart system. The design criteria were established and a prototype was developed. The environmental chamber testing results showed that, in a hot environment, the mean skin temperature (35.8℃ vs. 36.59℃), heart rate (110 beats/min vs. 116 beats/min), and core temperature of the subjects with the new cooling vest were significantly lower than those with the control (without the new cooling vest ). A significantly longer exercise time was obtained with the new cooling vest compared with the control (22.08 min vs. 11.08 min). Significant improvements in levels of coolness, dryness, comfort, and physical recovery were observed with the new cooling vest. Results suggest that the new cooling vest can reduce the thermal stress of construction workers and improve their work performance and comfort.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Thermoregulation and physiological responses · Climate Change and Health Impacts · Building Energy and Comfort Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Building and Real Estate, The Hong Kong Polytechnic University, Hong Kong SAR, China
School of Materials, University of Manchester, UK
Institute of Textiles & Clothing, The Hong Kong Polytechnic University, Hong Kong SAR, China
References (47)
Show source-provided references
1. Hong Kong Observatory. Monthly Weather Summary . http://gb.weather.gov.hk/wxinfo/pastwx/mwsc.htm (2012, accessed 10 February 2017).
2. 10.1016/j.buildenv.2012.12.01210.1016/j.buildenv.2012.12.012 ↗
3. 10.1016/j.ergon.2004.08.00310.1016/j.ergon.2004.08.003 ↗
4. Wisenews. Number of heat related incidents between 1998 and 2011 in Hong Kong. Wisenews , July 2012.
5. Shapiro Y · Aviat Space Environ Med · 1982 · 53 · 785
6. 10.1007/s00421-008-0716-810.1007/s00421-008-0716-8 ↗
7. 10.1007/BF0086502910.1007/BF00865029 ↗
8. 10.1080/0014013050012227610.1080/00140130500122276 ↗
9. 10.2486/indhealth.46.62010.2486/indhealth.46.620 ↗
10. 10.1007/s00421-007-0665-710.1007/s00421-007-0665-7 ↗
11. 10.1080/10803548.2008.1107674610.1080/10803548.2008.11076746 ↗
12. Occupational Safety and Health Council of Hong Kong (OSHC). Invitation to tender of contract study on effectiveness of personal equipment for protecting workers from heat stroke while working in a hot environment , March 2012, 26 pages. Hong Kong SAR, China: Occupational Safety and Health Council of Hong Kong (OSHC).
13. 10.1108/0955622971018549710.1108/09556229710185497 ↗
14. Dejonge JO · 1984
15. 10.1177/0887302X990170010210.1177/0887302X9901700102 ↗
16. 10.1177/0887302X020200040910.1177/0887302X0202000409 ↗
17. 10.1177/0887302X980160010610.1177/0887302X9801600106 ↗
18. 10.1080/1754326080199885510.1080/17543260801998855 ↗
19. 10.1080/00140139.2015.109873310.1080/00140139.2015.1098733 ↗
20. Hong Kong Observatory. Number of Very Hot days observed at the Hong Kong Observatory since 1884, exclude 1940–1946 . http://www.hko.gov.hk/cis/statistic/vhotday_statistic_e.htm (2017, accessed 10 February 2017).
21. Lamb JM · Clothing Text Res J · 1992 · 12 · 402
22. 10.1016/j.jtherbio.2015.01.00710.1016/j.jtherbio.2015.01.007 ↗
23. Guo YP, Chan APC, Wong FKW et al. Factors determining the preference for cooling vest across four industries in Hong Kong. RISUD Annual International Symposium 2016 (RAIS 2016) – Smart Cities , Hong Kong, 23–24 August 2016. Hong Kong SAR, China: Research Institute for Sustainable Urban Development, The Hong Kong Polytechnic University.
24. ASTM D1776 · 2004
25. Jeil Trading Co. Cooling Vest with Cooling Fan . http://www.ec21.com/product-details/Cooling-Vest-with-Cooling-Fan–9413270.html (2017, accessed 10 February 2017).
26. ASTM E96 · 2005
27. AS/NZS 4399:1996 · 1996
28. American Association of Textile Chemists and Colorists. AATCC technical manual, 2002. Water repellency-spray test, Research Triangle Park, NC: AATCC, 2002, pp. 65–67.
29. 10.1016/j.rser.2007.10.00510.1016/j.rser.2007.10.005 ↗
30. 10.3993/jfbi0620080210.3993/jfbi06200802 ↗
31. CIC (Construction Industry Council. Specifications for Supply and Delivery of Worker Uniforms for Construction Industry Council . (84) in P/AE/PUR/AGC, 2011.
32. Li Y · Comput Aided Des · 2008 · 38 · 726
33. 10.1016/j.cad.2008.06.00210.1016/j.cad.2008.06.002 ↗
34. Gagge AP · ASHRAE Trans · 1971 · 77 · 247
35. Hensel H · 1981
36. 10.1108/1472596121120040510.1108/14725961211200405 ↗
37. Iriki M. Textbook of Physiology on Body Temperature, Tokyo: Bunko-do, 2003, pp. 9.
38. 10.1177/004051751559177310.1177/0040517515591773 ↗
39. 10.3993/jfbi0920090910.3993/jfbi09200909 ↗
40. 10.1016/j.buildenv.2013.04.02110.1016/j.buildenv.2013.04.021 ↗
41. 10.1080/001401304200032771510.1080/0014013042000327715 ↗
42. Wright A · Int Nonwovens J · 2005 · 14 · 19
43. Corcoran S · Occup Health Saf · 2002 · 71 · 104
44. 10.1136/bjsm.2007.04368710.1136/bjsm.2007.043687 ↗
45. 10.1016/j.buildenv.2017.03.03210.1016/j.buildenv.2017.03.032 ↗
46. Zhao YJ · Ann Work Expo Health · 2017 · 1
47. 10.1016/j.jtherbio.2016.11.00210.1016/j.jtherbio.2016.11.002 ↗