Objective and subjective evaluation of the human thermal sensation of wet fabrics
Source abstract
Abstract
The aim of the current study was to investigate if human subjects can distinguish five different drying states of three different fabrics. We defined five time-points (drying states) for each fabric with an in-house developed infrared test, as well as gravimetrically. This test records the surface temperature of wetted fabrics with an infrared camera during the drying process. In addition, the weight course during drying was recorded. The subjects evaluated fabrics with different wetting and wicking behaviours in a perception questionnaire. They answered questions about thermal sensation, thermal comfort, pain sensation and wetness perception. In conclusion, the human subjects could not differentiate the drying states of the fabrics as long as they contained water. Only the last drying state (100% dry, as measured with the infrared test) was distinguishable from the other four. However, the dry time-point of a fabric measured with the gravimetric method did not coincide with the drying time measured with the infrared test or perceived by human subjects.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Textile materials and evaluations · Color perception and design · Thermoregulation and physiological responses
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Empa, Swiss Federal Laboratories for Materials Science and Technology, CH.
Institute of Human Movement Sciences and Sport, ETH, CH.
References (35)
Show source-provided references
1. Fanger PO · Br J Ind Med · 1973 · 30 · 313
2. Green BG · J Neuro Sci · 2004 · 61 · 13
3. Hensel H · 1981
4. 10.1007/BF0226902510.1007/BF02269025 ↗
5. 10.1080/001401304200032771510.1080/0014013042000327715 ↗
6. 10.1007/978-3-540-70658-8_1710.1007/978-3-540-70658-8_17 ↗
7. 10.1080/0040516010868895110.1080/00405160108688951 ↗
8. Winslow CEA · ASHVE Trans · 1939 · 44 · 179
9. 10.1007/s00421-009-0983-z10.1007/s00421-009-0983-z ↗
10. 10.1152/ajplegacy.1937.120.2.27710.1152/ajplegacy.1937.120.2.277 ↗
11. 10.1177/00405175950650050710.1177/004051759506500507 ↗
12. 10.1177/00405175950650060210.1177/004051759506500602 ↗
13. 10.1177/00405175900600070110.1177/004051759006000701 ↗
14. 10.1007/BF0287587710.1007/BF02875877 ↗
15. 10.1177/073168440808004610.1177/0731684408080046 ↗
16. 10.1111/j.1478-4408.1946.tb02387.x10.1111/j.1478-4408.1946.tb02387.x ↗
17. 10.1177/00405175000700081310.1177/004051750007000813 ↗
18. 10.1080/0040500740863035210.1080/00405007408630352 ↗
19. 10.1016/j.apenergy.2007.10.01610.1016/j.apenergy.2007.10.016 ↗
20. 10.1177/004051751036179610.1177/0040517510361796 ↗
21. 10.1152/japplphysiol.00612.200710.1152/japplphysiol.00612.2007 ↗
22. 10.1080/10803548.2008.1107675010.1080/10803548.2008.11076750 ↗
23. 10.1007/s00421-004-1137-y10.1007/s00421-004-1137-y ↗
24. 10.1016/j.jtherbio.2005.11.02710.1016/j.jtherbio.2005.11.027 ↗
25. 10.1016/j.buildenv.2009.02.01610.1016/j.buildenv.2009.02.016 ↗
26. 10.1016/j.buildenv.2006.06.03510.1016/j.buildenv.2006.06.035 ↗
27. Horrocks AR · 2000
28. 10.1520/STP17329S10.1520/STP17329S ↗
29. 1993
30. 10.1016/S0010-2180(02)00372-310.1016/S0010-2180(02)00372-3 ↗
31. Parsons K · 2003
32. 10.1016/j.jtherbio.2005.11.02810.1016/j.jtherbio.2005.11.028 ↗
33. 10.1111/j.1365-2702.2005.01121.x10.1111/j.1365-2702.2005.01121.x ↗
34. Hes L · 2001
35. 10.3109/0899022890914467710.3109/08990228909144677 ↗