The torso cooling of vests incorporated with phase change materials: a sweat evaporation perspective
Source abstract
Abstract
Cooling vests incorporated with phase change materials (PCMs) add extra insulation and restrict sweat evaporation. It is still unclear how much cooling benefit they can provide. The aim of this study was to investigate the torso cooling of the PCM vests in two hot environments: hot humid (HH, 34°C, 75% relative humidity (RH)) and hot dry (HD, 34°C, 37% RH). A pre-wetted torso fabric skin was used to simulate torso sweating on a thermal manikin. Three cooling vests incorporated with three melting temperatures ( T m ) of PCMs were tested ( T m = 21°C, T m = 24°C and T m = 28°C). They were worn under a military ensemble (total thermal insulation 1.60 clo; evaporative resistance 0.0516 kPaċm 2 /W), respectively. In a HH environment all the three cooling vests provided effective torso cooling; in a HD environment the cooling benefit was negative. In both environmental conditions, the evaporative cooling was greatly restricted by the cooling vests. The study indicated that when wearing the protective clothing with the relatively low evaporative resistance and when sweat production was high, the cooling vests were effective in a HH environment, but not in a HD environment.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Thermoregulation and physiological responses · Textile materials and evaluations · Infrared Thermography in Medicine
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Protective Clothing Research Center, Fashion Institute of Donghua University, China
Thermal Environment Laboratory, Department of Design Sciences, Faculty of Engineering, Lund University, Sweden
Empa, Swiss Federal Laboratories for Materials Science and Technology, Laboratory for Protection and Physiology, Switzerland
References (36)
Show source-provided references
1. 10.2486/indhealth.44.38810.2486/indhealth.44.388 ↗
2. Nunneley SA · Scand J Work Environ Health · 1989 · 15 · 52
3. 10.1016/j.apergo.2009.07.00110.1016/j.apergo.2009.07.001 ↗
4. 10.3357/ASEM.2411.200910.3357/ASEM.2411.2009 ↗
5. 10.1080/0014013950892509310.1080/00140139508925093 ↗
6. 10.1080/10803548.2006.1107668910.1080/10803548.2006.11076689 ↗
7. 10.1007/s00421-008-0924-210.1007/s00421-008-0924-2 ↗
8. ISO 7243. Hot environments-estimation of the heat stress on working man, based on the WBGT-index (wet bulb globe temperature), Geneva, International Standards Organization, 2003.
9. 10.1177/004051750935880010.1177/0040517509358800 ↗
10. 10.1080/0014013100373422910.1080/00140131003734229 ↗
11. 10.1007/s00421-009-1135-110.1007/s00421-009-1135-1 ↗
12. Kuklane K, Holmér I, Ohlsson G, et al. Heat stress in ventilated air tight coverall. In: Werner J and Hexamer M (eds) In: proceedings of the 9th international conference on environmental ergonomics (ICEE) , vol. 4, Shaker Verlag, Dortmund, 2000, pp.361-364.
13. 10.1007/s00421-011-1941-010.1007/s00421-011-1941-0 ↗
14. 10.1007/s00421-008-0716-810.1007/s00421-008-0716-8 ↗
15. 10.1007/s00421-008-0707-910.1007/s00421-008-0707-9 ↗
16. 10.1007/s00421-010-1748-410.1007/s00421-010-1748-4 ↗
17. 10.1152/japplphysiol.00979.200310.1152/japplphysiol.00979.2003 ↗
18. 10.1007/s00421-007-0665-710.1007/s00421-007-0665-7 ↗
19. 10.1007/BF0086502910.1007/BF00865029 ↗
20. 10.1080/0014013050012227610.1080/00140130500122276 ↗
21. 10.4085/1062-6050-45.2.16410.4085/1062-6050-45.2.164 ↗
22. 10.1016/j.jtherbio.2006.12.00110.1016/j.jtherbio.2006.12.001 ↗
23. 10.2486/indhealth.46.62010.2486/indhealth.46.620 ↗
24. 10.1080/0014013090358164910.1080/00140130903581649 ↗
25. Bendkowska W · Fibres Text East Eur · 2010 · 18 · 70
26. 10.1007/BF0085498210.1007/BF00854982 ↗
27. 10.2114/jpa.21.7510.2114/jpa.21.75 ↗
28. 10.1080/10803548.2008.1107674610.1080/10803548.2008.11076746 ↗
29. 10.1080/10803548.2004.1107659910.1080/10803548.2004.11076599 ↗
30. ASTM F2371. Standard test method for measuring the heat removal rate of personal cooling systems using a sweating heated manikin, West Conshohocken, 2010.
31. Gao C, Kuklane K and Holmér I. Thermoregulatory manikins are desirable for evaluations of intelligent clothing and smart textiles. In: proceedings of the 8th international meeting on thermal manikin and modeling (8I3M) , Victoria, Canada, 2010, pp.1–5.
32. 10.1007/s00484-011-0411-z10.1007/s00484-011-0411-z ↗
33. Wang F · Ann Occup Hyg · 2011 · 55 · 775
34. 10.3993/jfbi0320090810.3993/jfbi03200908 ↗
35. 10.1152/jappl.1974.36.3.31310.1152/jappl.1974.36.3.313 ↗
36. Wang F · Ind Textila · 2010 · 61 · 66