journal article·2011-02

Thermal protective performance of protective clothing used for low radiant heat protection

Guowen Song, Stephen Paskaluk, Rohit Sati, Elizabeth M Crown, J. Doug Dale, Mark Ackerman

Textile Research Journal· Volume 81· Issue 3
Publisher page

Abstract

A laboratory simulation was performed to study the thermal protective performance of fabric systems under low level thermal hazards in the range of 6.3—8.3 kW/m 2 . Two approaches were used. The first used a method similar to the ASTM F 1939, radiant heat resistance test, while the second used a modification designed to capture the contribution to skin burn injury due to energy stored in the test specimens being released after the direct exposure had ended. Both dry and wet specimens were tested. In order to accommodate the prolonged exposure time a water cooled heat flux sensor was used to calibrate the radiant heat source and measure the energy directly transmitted through during the exposure and discharged later from the fabric systems. The Henriques Burn Integral (HBI) was adopted and programmed with a three layer skin model to predict the time required to achieve a second degree skin burn injury. The study investigated the thermal protection provided by the clothing with different layering and examined the effect of moisture under low level radiant heat exposures. In addition, the physiological burden associated with wearing the clothing was predicted and compared. The results obtained show the difference in measured protection level under low radiant heat from these two approaches and demonstrate that the stored thermal energy released from the clothing system significantly lowers the measured thermal protective performance.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Thermoregulation and physiological responses · Textile materials and evaluations · Infrared Thermography in Medicine

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

University of Alberta, Edmonton, Canada,

University of Alberta, Edmonton, Canada

References (22)

Show source-provided references
1. Foster JA · Fire Engineers Journal · 1995 · 55 · 30
2. 10.1177/15280837760060010610.1177/152808377600600106 ↗
3. 10.1016/0379-7112(81)90011-410.1016/0379-7112(81)90011-4 ↗
4. 10.1177/00405175870570030110.1177/004051758705700301 ↗
5. 10.1177/00405175000700070210.1177/004051750007000702 ↗
6. 10.1177/00405175840540100310.1177/004051758405401003 ↗
7. 10.1177/00405175830530080610.1177/004051758305300806 ↗
8. 10.1177/0887302X980160020310.1177/0887302X9801600203 ↗
9. 10.1177/00405175040740120110.1177/004051750407401201 ↗
10. 10.1177/00405175790490040410.1177/004051757904900404 ↗
11. Utech HP · International Fire Chief · 1973 · 39 · 26
12. Lawson JR Fire fighters protective clothing and thermal environments of structural fire fighting, performance of protective clothing. In: Stull JO and Schwope AD (eds) Performance of protective clothing, ASTM STP 1273, 6th Volume West Conshohocken, PA: American Society for Testing and Materials, 1997, pp.334-352.10.1520/STP19915S ↗
13. Song G.
14. 10.1177/004051750605394710.1177/0040517506053947 ↗
15. 10.1177/07349041860040050210.1177/073490418600400502 ↗
16. Stull JO The effect of moisture on firefighter protective clothing thermal insulation: A review of industry research. In: Nelson CN and Henry NW (eds) Performance of protective clothing, ASTM STP 1386, 7th Volume West Conshohocken, PA: American Society for Testing and Materials, 2000, pp.557-576.
17. 10.1177/004051750708130910.1177/0040517507081309 ↗
18. 10.1080/1545962049043211410.1080/15459620490432114 ↗
19. 10.1016/S0003-4878(99)00051-410.1016/S0003-4878(99)00051-4 ↗
20. Gempel RF · prepared for the National Fire Prevention and Control Administration · 1977
21. 10.1177/00405175980680110210.1177/004051759806801102 ↗
22. 10.1520/STP19903S10.1520/STP19903S ↗