journal article·2014-08

Amperometric urea biosensor based on covalently immobilized urease on an electrochemically polymerized film of polyaniline containing MWCNTs

Azam S. Emami Meibodi, Sara Haghjoo

Synthetic Metals· Volume 194
Publisher page

Abstract

Abstract In this work, polyaniline-multiwalled carbon nanotubes (PANI/MWCNTs) composite were fabricated by electropolymerization method, as a matrix for entrapment of enzyme. Urease has been immobilized by using physical adsorption and electrochemical entrapment technique. A conventional three-electrode system was used. Pencil graphite disk electrode (PGDE), Ag/AgCl (3 M KCl) and platinum wire were used as working electrode, reference electrode and counter electrode respectively. The influence of several experimental parameters such as applied potential, type and concentrate of dopant and enzyme loading was explored to optimize the electroanalytical performance of the biosensor. The responses of the enzyme electrodes were measured via monitoring amperometric current at +0.3 V (vs. Ag/AgCl). Kinetic parameters operational and storage stabilities were determined. The value of the apparent Michaelis–Menten constant, Imax and sensitivity (Imax/Km) experimentally determined to be 2.02 mM, 2.5 × 10−5 A cm−2 and 12 × 10−5 A mM−1 cm−2, respectively. The optimized urea biosensor shows a good sensitivity from 10−2 M to 10−5 M urea concentration range and a response time of about 50 s. The detection limit was 0.04 mM. The proposed biosensor retained 50% of its original response after 15 days.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Conducting polymers and applications · Electrochemical Analysis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Potentiometric bioelectronic tongue for the analysis of urea and alkaline ions in clinical samples10.1016/j.bios.2006.10.007 ↗
2. Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films10.1016/j.bios.2003.12.035 ↗
3. Analytical methodology for the determination of urea current practice and future trends10.1016/S0165-9936(02)00507-1 ↗
4. Detection of urea in milk by spectrophotometry to p-dimethylaminobenzaldehyde as chromogenic reagent
5. Analytical methods for measuring urea in pharmaceutical formulations10.1016/S0731-7085(96)01978-4 ↗
6. Voltammetric detection of urea on an Ag-modified zeolite-expanded graphite–epoxy composite electrode10.3390/s8095806 ↗
7. Ionic effect investigation of a potentiometric sensor for urea and surface morphology observation of entrapped urease/polypyrrole matrix10.1016/j.bios.2009.01.036 ↗
8. Clinical analysis of urea in human blood by coupling a surface acoustic wave sensor with urease extracted from pumpkin seeds10.1016/0003-2670(95)00046-3 ↗
9. Potentiometric ion and bioselective electrodes based on asymmetric polyurethane membranes10.1016/0003-2670(93)80602-H ↗
10. Biosensor array based on polyaniline10.1021/ac950655w ↗
11. Coulometric flow analyzer for use with immobilized enzyme reactors10.1021/ac50029a030 ↗
12. Polypyrrole-based amperometric flow injection biosensor for urea10.1016/0003-2670(95)00562-5 ↗
13. Electrochemical sensor for measurement of urea and creatinine in serum based on ac impedance measurement of enzyme-catalyzed polymer transformation10.1021/ac981367d ↗
14. Aminiaturized urea sensor based on the integration of both ammonium based urea enzyme field effect transistor and a reference field effect transistor in a single chip10.1016/S0039-9140(99)00122-8 ↗
15. A specific enzyme electrode for urea10.1016/S0003-2670(01)85472-6 ↗
16. A comparative study of immobilization techniques for urease on glass-pH-electrode and its application in urea detection in blood serum10.1016/j.aca.2006.06.063 ↗
17. Amperometric enzyme electrode for urea determination using immobilized urease in poly(vinylferrocenium) film10.1016/j.snb.2005.05.026 ↗
18. Maaref · Sens. Actuators B: Chem. · 2007 · 123 · 67110.1016/j.snb.2006.10.010 ↗
19. Dhawan · Biochem. Eng. J. · 2009 · 44 · 4210.1016/j.bej.2008.07.004 ↗
20. Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films10.1016/j.bios.2003.12.035 ↗
21. Potentiometric enzyme electrode for urea determination using immobilized urease in poly(vinylferrocenium) film10.1016/j.snb.2004.12.043 ↗
22. Pulsed-amperometric detection of urea in blood samples on a conducting polypyrrole–urease biosensor10.1016/S0003-2670(96)00502-8 ↗
23. Nanotubes from carbon10.1021/cr970102g ↗
24. An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film10.1016/j.biomaterials.2004.09.024 ↗
25. Electrochemistry and scanning electron microscopy of polyaniline/peroxidase-based biosensor10.1016/j.talanta.2003.11.050 ↗
26. Lawton · J. Mol. Liquids · 1989 · 42 · 8310.1016/0167-7322(89)80027-3 ↗
27. Canh · 1993 · 46