journal article·2021-09

Radiation protection assessment of gamma photons in 64TeO2–10WO3–10Nb2O5– 15KF–1La2O3 glasses doped with Tm2O3 using photon-shielding and dosimetry software

Medical and Clinical Affairs Department, King Faisal Medical City, Abha 62523, Saudi Arabia, A. M. Alqahtani, M. S. Alqahtani, Department of Radiological Sciences, College of Applied Medical Sciences, King Khalid University, Abha 61421, Saudi Arabia, BioImaging Unit, Space Research Centre, Department of Physics and Astronomy, University of Leicester, Leicester LE1 7RH, UK, K. I. Hussein, Department of Radiological Sciences, College of Applied Medical Sciences, King Khalid University, Abha 61421, Saudi Arabia, Department of Medical Physics and Instrumentation, National Cancer Institute, University of Gezira, Wad Medani 20, Sudan, A. J. Alkulib, Department of Radiological Sciences, College of Applied Medical Sciences, King Khalid University, Abha 61421, Saudi Arabia, F.F. Alqahtani, Department of Radiological Sciences, College of Applied Medical Sciences, Najran University, Najran 1988, Saudi Arabia, E. Yousef, Research Center for Advanced Materials Science (RCAMS), King Khalid University, Abha 61421, Saudi Arabia, Physics Department, Faculty of Science, King Khalid University, Abha 61421, Saudi Arabia, Physics Department, Faculty of Science, Al Azhar University, Assiut branch, Egypt

Chalcogenide Letters· Volume 18· Issue 9
Publisher page

Abstract

Radiation-shielding applications are necessary to protect against deleterious effects of radiation. This study tested thulium oxide (Tm2O3) added to the glass-system composition 64TeO2–10WO3–10Nb2O5–15KF–1La2O3. Adding Tm2O3 increased sample density from 5.22 to 5.40 g/cm3 and measured at photon energy of 15 keV–15 MeV. Multiple radiationshielding parameters were evaluated and assessed using photon-shielding and dosimetry software, including linear and mass attenuation coefficients, half-value layers, mean free paths, atomic and electronic cross sections, effective atomic numbers, effective electron density, and exposure buildup factors. Half-value layer and mean free-path values were compared with those of well-known radiation-shielding materials, ie, conventional concrete and commercial glasses. Atomic and electronic cross-section values effectively increased with the addition of thulium oxide to the glass systems. While the highest linear and attenuation coefficients were 242–281 cm2 /g at 15 keV, the denser glass recorded the highest mass attenuation coefficients value of 52.17 cm2 /g across all samples. The highest effective atomic number and effective electron density were recorded for the denser glass, because it had the highest thulium oxide fraction and was more burdened by interaction with photon energy. Half-value layers and mean free paths showed similar behavior, and high-density materials achieved low values. At high energy, exposure buildup-factor values increased, while at low energy, values decreased.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiation Shielding Materials Analysis · Nuclear materials and radiation effects · Glass properties and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References

Reference metadata was not supplied for this record.