journal article·2024-05-14

Postoperative Long-Term Monitoring of Mechanical Characteristics in Reconstructed Soft Tissues Using Biocompatible, Immune-Tolerant, and Wireless Electronic Sutures

Mugeun Lee, Yeontaek Lee, Ji Hye Choi, Hwajoong Kim, Daun Jeong, Kijun Park, Jinho Kim, Jae Park, Woo Young Jang, Jungmok Seo, Jaehong Lee

ACS Nano· Volume 18· Issue 19
Publisher page

Abstract

Accurate postoperative assessment of varying mechanical properties is crucial for customizing patient-specific treatments and optimizing rehabilitation strategies following Achilles tendon (AT) rupture and reconstruction surgery. This study introduces a wireless, chip-less, and immune-tolerant in vivo strain-sensing suture designed to continuously monitor mechanical stiffness variations in the reconstructed AT throughout the healing process. This innovative sensing suture integrates a standard medical suturing thread with a wireless fiber strain-sensing system, which incorporates a fiber strain sensor and a double-layered inductive coil for wireless readout. The winding design of Au nanoparticle-based fiber electrodes and a hollow core contribute to the fiber strain sensor's high sensitivity (factor of 6.2 and 15.1 pF for revised sensitivity), negligible hysteresis, and durability over 10,000 stretching cycles. To ensure biocompatibility and immune tolerance during extended in vivo periods, an antibiofouling lubricant layer was applied to the sensing suture. Using this sensing system, we successfully monitored the strain responses of the reconstructed AT in an in vivo porcine model. This facilitated the postoperative assessment of mechanical stiffness variations through a well-established analytical model during the healing period.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Tendon Structure and Treatment · Knee injuries and reconstruction techniques · Sports injuries and prevention

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Robotics and Mechatronics Engineering, DGIST Daegu 42988, Republic of Korea

School of Electrical and Electronic Engineering, Yonsei University Seoul 03722, Republic of Korea

Department of Orthopedic Surgery, Korea University College of Medicine Seoul 02841, Republic of Korea

Institute of Nanobiomarker-Based Medicine, Korea University, Seoul 02841, Republic of Korea

Funding

Ministry of Health and Welfare · Ministry of Food and Drug Safety · Ministry of Science and ICT, South Korea · National Research Foundation of Korea · Ministry of Trade, Industry and Energy

References (50)

Show source-provided references
1. Maquirriain J. · Yale J. Biol. Med. · 2011 · 84 · 289
2. 10.1007/s00223-014-9915-y10.1007/s00223-014-9915-y ↗
3. 10.1177/194173810935043810.1177/1941738109350438 ↗
4. Biewener A. · 2008 · 26910.1007/978-0-387-73906-9_10 ↗
5. 10.1002/jor.2462110.1002/jor.24621 ↗
6. 10.1002/jcsm.1223810.1002/jcsm.12238 ↗
7. 10.1016/j.actbio.2017.08.03210.1016/j.actbio.2017.08.032 ↗
8. 10.1186/1758-2555-1-1410.1186/1758-2555-1-14 ↗
9. 10.1111/sms.1220910.1111/sms.12209 ↗
10. Gomes M. E. · 2015
11. 10.1016/j.jbiomech.2018.08.01610.1016/j.jbiomech.2018.08.016 ↗
12. 10.1007/s10439-012-0538-z10.1007/s10439-012-0538-z ↗
13. 10.1186/1471-2474-8-11610.1186/1471-2474-8-116 ↗
14. 10.1177/036354651244792610.1177/0363546512447926 ↗
15. 10.1016/j.fas.2018.04.00410.1016/j.fas.2018.04.004 ↗
16. 10.1302/2046-3758.118.BJR2021-0576.R110.1302/2046-3758.118.BJR2021-0576.R1 ↗
17. 10.1016/j.clinbiomech.2015.03.00510.1016/j.clinbiomech.2015.03.005 ↗
18. 10.1177/036354651453101410.1177/0363546514531014 ↗
19. 10.4085/1062-6050-52.1.0410.4085/1062-6050-52.1.04 ↗
20. 10.1016/j.clinbiomech.2008.02.00210.1016/j.clinbiomech.2008.02.002 ↗
21. 10.1007/s00402-017-2627-910.1007/s00402-017-2627-9 ↗
22. 10.1007/s00466-010-0567-010.1007/s00466-010-0567-0 ↗
23. 10.1038/s41928-018-0071-710.1038/s41928-018-0071-7 ↗
24. 10.1021/acsnano.6b0269310.1021/acsnano.6b02693 ↗
25. 10.1002/admt.20220204110.1002/admt.202202041 ↗
26. 10.1002/adhm.20200085510.1002/adhm.202000855 ↗
27. 10.1088/0960-1317/20/8/08500510.1088/0960-1317/20/8/085005 ↗
28. 10.1038/s41598-017-01009-710.1038/s41598-017-01009-7 ↗
29. 10.1002/admt.20180003110.1002/admt.201800031 ↗
30. 10.1002/smtd.20230050110.1002/smtd.202300501 ↗
31. 10.1002/adhm.20230161010.1002/adhm.202301610 ↗
32. 10.1038/s41563-020-00814-210.1038/s41563-020-00814-2 ↗
33. 10.1038/s41467-021-23802-910.1038/s41467-021-23802-9 ↗
34. 10.1038/s41467-023-37948-110.1038/s41467-023-37948-1 ↗
35. 10.1002/adfm.20170200910.1002/adfm.201702009 ↗
36. 10.1038/s41928-021-00557-110.1038/s41928-021-00557-1 ↗
37. 10.1126/sciadv.abb002510.1126/sciadv.abb0025 ↗
38. 10.1021/acsami.1c0987910.1021/acsami.1c09879 ↗
39. 10.1002/kin.2111510.1002/kin.21115 ↗
40. 10.1109/JSEN.2007.91238610.1109/JSEN.2007.912386 ↗
41. 10.1002/mabi.20180011210.1002/mabi.201800112 ↗
42. 10.1038/nature1044710.1038/nature10447 ↗
43. 10.1002/advs.20210023110.1002/advs.202100231 ↗
44. 10.1182/blood.V55.1.156.15610.1182/blood.V55.1.156.156 ↗
45. 10.1016/j.addr.2019.08.01010.1016/j.addr.2019.08.010 ↗
46. 10.1002/term.145910.1002/term.1459 ↗
47. 10.1002/jbm.b.3317110.1002/jbm.b.33171 ↗
48. 10.1186/s13018-016-0451-510.1186/s13018-016-0451-5 ↗
49. 10.1093/asj/sjz03610.1093/asj/sjz036 ↗
50. 10.1136/bjsports-2016-09610610.1136/bjsports-2016-096106 ↗