journal article·2024-08-27Open access

Insertable Glucose Sensor Using a Compact and Cost-Effective Phosphorescence Lifetime Imager and Machine Learning

Artem Goncharov, Zoltan Gorocs, Ridhi Pradhan, Brian Ko, Ajmal Ajmal, Andres Rodriguez, David Baum, Marcell Veszpremi, Xilin Yang, Maxime Pindrys, Tianle Zheng, Oliver Wang, Jessica C. Ramella-Roman, Michael J. McShane, Aydogan Ozcan

ACS Nano· Volume 18· Issue 34

Abstract

Optical continuous glucose monitoring (CGM) systems are emerging for personalized glucose management owing to their lower cost and prolonged durability compared to conventional electrochemical CGMs. Here, we report a computational CGM system, which integrates a biocompatible phosphorescence-based insertable biosensor and a custom-designed phosphorescence lifetime imager (PLI). This compact and cost-effective PLI is designed to capture phosphorescence lifetime images of an insertable sensor through the skin, where the lifetime of the emitted phosphorescence signal is modulated by the local concentration of glucose. Because this phosphorescence signal has a very long lifetime compared to tissue autofluorescence or excitation leakage processes, it completely bypasses these noise sources by measuring the sensor emission over several tens of microseconds after the excitation light is turned off. The lifetime images acquired through the skin are processed by neural network-based models for misalignment-tolerant inference of glucose levels, accurately revealing normal, low (hypoglycemia) and high (hyperglycemia) concentration ranges. Using a 1 mm thick skin phantom mimicking the optical properties of human skin, we performed in vitro testing of the PLI using glucose-spiked samples, yielding 88.8% inference accuracy, also showing resilience to random and unknown misalignments within a lateral distance of ∼4.7 mm with respect to the position of the insertable sensor underneath the skin phantom. Furthermore, the PLI accurately identified larger lateral misalignments beyond 5 mm, prompting user intervention for realignment. The misalignment-resilient glucose concentration inference capability of this compact and cost-effective PLI makes it an appealing wearable diagnostics tool for real-time tracking of glucose and other biomarkers.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Optical Imaging and Spectroscopy Techniques · Spectroscopy Techniques in Biomedical and Chemical Research · Electrochemical sensors and biosensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Electrical & Computer Engineering Department, University of California, Los Angeles, California 90095, United States

Bioengineering Department, University of California, Los Angeles, California 90095, United States

California NanoSystems Institute (CNSI), University of California, Los Angeles, California 90095, United States

Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, United States

Department of Biomedical Engineering, Florida International University, Miami, Florida 33199, United States

Department of Physics, University of Connecticut, Storrs, Connecticut 06269, United States

Department of Computer Science, University of California, Los Angeles, California 90095, United States

Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States

Department of Surgery, University of California, Los Angeles, California 90095, United States

Funding

National Science Foundation

References (73)

Show source-provided references
1. 10.3390/bios1302018110.3390/bios13020181 ↗
2. 10.3390/bios1203016810.3390/bios12030168 ↗
3. 10.1038/s41427-018-0086-610.1038/s41427-018-0086-6 ↗
4. 10.1021/acssensors.8b0121810.1021/acssensors.8b01218 ↗
5. 10.1109/JSEN.2019.291632010.1109/JSEN.2019.2916320 ↗
6. 10.1039/D0NR03446K10.1039/D0NR03446K ↗
7. 10.1002/elan.20210027310.1002/elan.202100273 ↗
8. 10.1149/2754-2726/ac7abb10.1149/2754-2726/ac7abb ↗
9. 10.1039/D1AN00283J10.1039/D1AN00283J ↗
10. 10.22034/ABEC.2023.2012575.138310.22034/ABEC.2023.2012575.1383 ↗
11. 10.1039/C7TC05204A10.1039/C7TC05204A ↗
12. 10.1109/LSENS.2023.326718010.1109/LSENS.2023.3267180 ↗
13. 10.1007/s00604-022-05228-210.1007/s00604-022-05228-2 ↗
14. 10.1038/s41565-023-01513-010.1038/s41565-023-01513-0 ↗
15. 10.3390/chemosensors908019510.3390/chemosensors9080195 ↗
16. 10.1039/D2RA02008D10.1039/D2RA02008D ↗
17. 10.1039/D1BM01136G10.1039/D1BM01136G ↗
18. 10.3390/s2005137910.3390/s20051379 ↗
19. 10.1038/s41378-022-00443-610.1038/s41378-022-00443-6 ↗
20. 10.1016/j.trac.2023.11696510.1016/j.trac.2023.116965 ↗
21. 10.1016/j.elecom.2022.10731410.1016/j.elecom.2022.107314 ↗
22. 10.1038/s41551-022-00887-110.1038/s41551-022-00887-1 ↗
23. 10.1038/s41551-022-00998-910.1038/s41551-022-00998-9 ↗
24. 10.1177/193229682091191910.1177/1932296820911919 ↗
25. 10.1039/D1SD00030F10.1039/D1SD00030F ↗
26. 10.1080/10408347.2021.200822710.1080/10408347.2021.2008227 ↗
27. 10.1016/S2213-8587(13)70112-810.1016/S2213-8587(13)70112-8 ↗
28. 10.1016/j.diabres.2019.10784310.1016/j.diabres.2019.107843 ↗
29. 10.2522/ptj.2008002010.2522/ptj.20080020 ↗
30. 10.2147/MDER.S2813410.2147/MDER.S28134 ↗
31. 10.1021/cr500562m10.1021/cr500562m ↗
32. 10.2337/dc20-225010.2337/dc20-2250 ↗
33. 10.2337/dc19-207310.2337/dc19-2073 ↗
34. 10.2337/dc20-285610.2337/dc20-2856 ↗
35. 10.1089/dia.2017.032110.1089/dia.2017.0321 ↗
36. 10.1177/193229681560186910.1177/1932296815601869 ↗
37. 10.1080/05704928.2018.148632410.1080/05704928.2018.1486324 ↗
38. 10.1177/19322968130070010310.1177/193229681300700103 ↗
39. 10.2337/dc16-152510.2337/dc16-1525 ↗
40. 10.1039/D1AN00283J10.1039/D1AN00283J ↗
41. 10.1007/s10544-015-9983-410.1007/s10544-015-9983-4 ↗
42. 10.1177/193229681775093210.1177/1932296817750932 ↗
43. 10.1021/ac202343e10.1021/ac202343e ↗
44. 10.1089/dia.2019.015910.1089/dia.2019.0159 ↗
45. 10.1089/dia.2018.039710.1089/dia.2018.0397 ↗
46. 10.1016/j.mvr.2019.02.00210.1016/j.mvr.2019.02.002 ↗
47. 10.3390/s2004095910.3390/s20040959 ↗
48. 10.1021/cm990624810.1021/cm9906248 ↗
49. 10.1002/chem.20120377410.1002/chem.201203774 ↗
50. 10.1177/193229681559043910.1177/1932296815590439 ↗
51. 10.3390/bios701000810.3390/bios7010008 ↗
52. 10.1101/2024.07.21.60450210.1101/2024.07.21.604502 ↗
53. 10.1146/annurev-anchem-061417-12595610.1146/annurev-anchem-061417-125956 ↗
54. 10.1038/s42256-021-00360-910.1038/s42256-021-00360-9 ↗
55. 10.1109/ACCESS.2021.309877710.1109/ACCESS.2021.3098777 ↗
56. 10.1109/TIM.2023.333436610.1109/TIM.2023.3334366 ↗
57. 10.1021/acsnano.6b0512910.1021/acsnano.6b05129 ↗
58. Blood Sugar Test. https://www.ucsfhealth.org/medical-tests/blood-sugar-test (accessed April 14, 2024).
59. Testing for Diabetes. https://www.cdc.gov/diabetes/diabetes-testing/(accessed April 14, 2024).
60. About Low Blood Sugar (Hypoglycemia). https://www.cdc.gov/diabetes/about/low-blood-sugar-hypoglycemia.html (accessed April 14, 2024).
61. Prediabetes – Your Chance to Prevent Type 2 Diabetes. https://www.cdc.gov/diabetes/prevention-type-2/prediabetes-prevent-type-2.html (accessed April 14, 2024).
62. 10.1007/s00018-011-0914-010.1007/s00018-011-0914-0 ↗
63. 10.1016/S0003-2697(02)00384-610.1016/S0003-2697(02)00384-6 ↗
64. ANSI Z136 · 2014
65. 10.1039/D2TB02339C10.1039/D2TB02339C ↗
66. 10.1126/sciadv.170154810.1126/sciadv.1701548 ↗
67. 10.1109/TPAMI.2020.298748910.1109/TPAMI.2020.2987489 ↗
68. Ascensão, B.; Santos, P.; Dias, M. Distance measurement system for medical applications based on the NanEye stereo camera. In International Conference on Biomedical Engineering and Applications (ICBEA) 2018, pp 1–6.10.1109/ICBEA.2018.8471728.10.1109/ICBEA.2018.8471728 ↗
69. Dexcom G7 CGM System. https://www.dexcom.com/guides (accessed July 20, 2024).
70. FreeStyle Libre. https://www.support.freestyle.abbott/hc/en-us (accessed July 20, 2024).
71. 10.3390/bios1301014110.3390/bios13010141 ↗
72. 10.1111/j.1751-1097.2012.01220.x10.1111/j.1751-1097.2012.01220.x ↗
73. Prahl, S. Everything I Think You Should Know about Inverse Adding-Doubling; OMLC, 2011.