journal article·2007-09

Suitability analysis of selective solar absorber surfaces based on a total cost accounting approach

Bo Carlsson

Publisher page

Abstract

By adopting a total cost counting approach a sputtered solar absorber coating is compared with an electrochemically produced solar absorber coating for the application of domestic hot water production. The comparison is made assuming a 25 years service time and takes into account production cost, cost associated with initial non-ideal optical performance, possible cost due to reduction in long-term performance, end-of-life cost, and possible cost associated with ecological damage. The result from the analysis gives an understanding of the relative importance of the various factors contributing to the total cost and shows that the sputtered coating seems more favourable to the electrochemical coating in all respects.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Solar Thermal and Photovoltaic Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (13)

Show source-provided references
1. B. Carlsson, Y. Virtanen, J.O. Nøkleby, R. Sandström, A holistic approach to materials selection in component design, NT Technical Report 476, Nordic Innovation Centre, Stensberggata. 25, No-0170 Oslo, Norway, 〈www.nordicinnovation.net〉.
2. B. Carlsson, D. Taylor, W. Hogland, M. Marques, et al., Design of functional units for products by a total cost accounting approach, VINNOVA Report VR 2007:1 (ISBN 978-91-85084-70-8)Feb. 2007.
3. Wäckelgård · Sol. Energy Mater. Sol. Cells · 1998 · 54 · 16510.1016/S0927-0248(98)00067-1 ↗
4. B. Carlsson, U. Frei, M. Köhl, K. Möller, Accelerated life testing of solar energy materials—case study of some selective solar absorber coating materials for DHW systems, Technical Report of the International Energy Agency Solar Heating and Cooling Programme Task 10 on Solar Materials Research and Development, SP Report 1994, p. 13, ISBN 91-7848-472-3.
5. Brunold · Sol. Energy Mater. Sol. Cells · 2000 · 61 · 23910.1016/S0927-0248(99)00113-0 ↗
6. Sunstrip AB Private communication 2001, 〈www.sunstrip.com〉, and Jan-Olof Dalenbäck, Chalmers Technical University, Gothenburg, Sweden.
7. Carlsson · Sol. Energy Mater. Sol. Cells · 2004 · 84 · 25510.1016/j.solmat.2004.01.046 ↗
8. Initial risk analysis and potential failure modes
9. Standard ECSS-30-02A from ESA Publication Division ESTEC, P.O. Box 299, 2200 AG Noordwijk, The Netherlands.
10. Carlsson · Sol. Energy Mater. Sol. Cells · 2000 · 61 · 22310.1016/S0927-0248(99)00112-9 ↗
11. M. Goedkoop, R. Spriensma, The Eco-indicator 99—A damage oriented method for Life Cycle Impact Assessment, 21 juni 2001, Pré Consultants B.V., Plotterweg 12, 3821BB Amersfoort, The Netherlands, 〈www.pre.nl〉.
12. B. Steen, EPS-Default valuation of environmental impacts from emission and use of resources version 1996, AFR-REPORT 111, Swedish Environmental Research Institute, IVL, Göteborg.
13. SIMA PRO 6 LCA software, PRé Consultants B.V., Plotterweg 12, 3821 BB Amersfoort, The Netherlands, 〈www.pre.nl/simapro〉.