Tilt angle dependence of output power in an 80kWp hybrid PV system installed at Shiga in Japan
Source abstract
Abstract
One-year field experience of an 80 kW PV system on a rooftop of the ROHM Memorial VLSI Research Center at the Ritsumeikan University is reported. All kinds of live technology available materials, c-Si, poly Si and a-Si solar cells are installed on the three tilt angles of 26.5° south, horizontal and north 26.5°. Systematic PV performances have been measured from the beginning of June 2000 to the end of May 2001. Measurements were made mainly on DC output power from four kinds of PV arrays; c-Si south side, a-Si of horizontal and poly Si, a-Si north side. It has been shown from analyses of monthly data on each material that almost 70% of with that in the south side in the annual average. In summer a-Si module yields the maximum output power normalized to 1 kWp. On the contrary c-Si module shows larger output in winter. Some other unique results are demonstrated and discussed.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Photovoltaic System Optimization Techniques · solar cell performance optimization · Photovoltaic Systems and Sustainability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (2)
Show source-provided references
1. K. Shibata, Y. Utijima, The distribution of the solar energy and measurement, Japan Scientific Societies Press, pp. 41–49.
2. Evaluation of electric performance by democratic module PV system field test10.1016/S0927-0248(00)00312-3 ↗