Development and performance test of smart power conditioner for value-added PV application
Source abstract
Abstract
Abstract It is a disadvantage that PV power generation is only useful for clear daytime. However, a new 24 hours of application in an extended area can be added by active utilization of potential ability of PV power conditioner. For this purpose, a new multi-functional power conditioner was developed, which has a smoothing function to reduce PV output variation and load fluctuation, and also has additional function to compensate harmonics current and reactive power caused by customer's load. As a result of indoor testing, a reduction rate of around 1 20 for harmonics current and reactive power were achieved. In addition, the reduction rate around 1 10 for smoothing of PV output variation and load fluctuation were verified. The work was promoted by NEDO as part of the New Sunshine Project in Japan.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Power Systems and Renewable Energy · Smart Grid Energy Management · Photovoltaic System Optimization Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (2)
Show source-provided references
1. K. Takigawa, N. Okada, et al., A Development of Smart PV Inverter for Value Added PV Application, 28tth IEEE PVSC, Anchorage, Alaska, September, 2000.10.1109/PVSC.2000.916218 ↗
2. N. Kuwabara, K. Takigawa, et al., A Development of Multi Functional PV Inverter for Value Added PV Application, JSES Research Meeting, Kanazawa, Japan, November, 2000, only Japanese.10.1109/PVSC.2000.916218 ↗