Experimental performance characteristics of the daytime radiative cooler at various surface orientations
Source abstract
Abstract
The daytime radiative cooling technology is becoming crucial with several prospective applications, either as a standalone or in conjunction with conventional cooling systems ; however, the dilute cooling flux is a main drawback. The cooling flux can be enhanced by proper surface orientation (direction or azimuth and tilting or inclination), but it has not been studied extensively. Hence, this study describes the radiative cooler`s angular and directional-dependent performance. The angular and directional dependent study is essential to emphasize the further development in the radiative coatings` suitable macro-scale geometry. An optimized polymer-particle composite structured daytime radiative cooler has been developed and tested with maximum temperature drop from the ambient as an objective function. The north-facing radiative cooler starts to perform better up to a 30° tilt angle; after that, its performance tends to decrease. The south-facing surfaces have reduced performance due to higher solar flux exposure as well as reduced sky exposure. A flat surface receives the maximum sky exposure since its horizontal placement does not interfere with the earth`s objects. A maximum of 10.5 °C temperature drop and an average maximum of 5.5 °C are observed. North-facing tilt up to 30° is recommended in the northern hemisphere and vice-versa for best performance.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Thermal Radiation and Cooling Technologies · Building Energy and Comfort Optimization · Urban Heat Island Mitigation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Tackling climate change through radiative cooling10.1016/j.joule.2019.07.010 ↗
2. Worldwide potential of emissive materials based radiative cooling technologies to mitigate urban overheating10.1016/j.buildenv.2023.110694 ↗
3. Review on passive daytime radiative cooling : fundamentals, recent researches, challenges and opportunities10.1016/j.rser.2020.110263 ↗
4. Climate change influences in the determination of the maximum power potential of radiative cooling. Evolution and seasonal study in Europe10.1016/j.renene.2023.05.083 ↗
5. A review of the application of radiative sky cooling in buildings: challenges and optimization10.1016/j.enconman.2022.115768 ↗
6. Environmental effect on the performance of passive daytime photonic radiative cooling and building energy-saving potential10.1016/j.jclepro.2020.123119 ↗
7. Hierarchically porous polymer coatings for highly efficient passive daytime radiative cooling10.1126/science.aat9513 ↗
8. Cellulose-upgraded polymer films for radiative sky cooling10.1016/j.jqsrt.2021.107824 ↗
9. Double-layer nanoparticle-based coatings for efficient terrestrial radiative cooling10.1016/j.solmat.2017.04.020 ↗
10. Cellulose-based porous polymer film with auto-deposited TiO2 as spectrally selective materials for passive daytime radiative cooling10.1016/j.optmat.2021.111431 ↗
11. CaCO3 micro particle-based radiative cooling device without metal reflector for entire day
12. Daytime radiative cooling capacity of nanoparticle on thermoplastic polyurethane (TPU) film10.1016/j.solener.2022.09.029 ↗
13. Experimental and numerical study on the potential of a new radiative cooling paint boosted by SiO2 microparticles for energy saving10.1016/j.energy.2023.128473 ↗
14. Ultrawhite BaSO4 paints and films for remarkable daytime subambient radiative cooling10.1021/acsami.1c02368 ↗
15. Experimentally optimized particle–polymer matrix structure for efficient daytime radiative cooling10.1063/5.0098335 ↗
16. Concentrated radiative cooling10.1016/j.apenergy.2021.118368 ↗
17. Performance evaluation of various strategies to improve sub-ambient radiative sky cooling10.1016/j.renene.2021.01.103 ↗
18. Quantitative characterization of the effect of inclination angle on flat-plate radiative cooling performance in buildings
19. Impact of aging, precipitation, and orientation on performance of radiative cooling for building envelope: a field investigation10.1016/j.enbuild.2022.112716 ↗
20. Sub-ambient daytime radiative cooling based on continuous sunlight blocking10.1016/j.solmat.2022.111854 ↗
21. A generalized solar and thermal management strategy for daytime radiative cooling10.1016/j.applthermaleng.2023.121095 ↗
22. Performance improvement of CO2 air conditioner by integrating photonic radiative cooler as sub-cooler or/and roof envelope
23. A set of equations for full spectrum and 8- to 14-μm and 10.5- to 12.5-μm thermal radiation from cloudless skies10.1029/WR017i002p00295 ↗
24. A polydimethylsiloxane-coated metal structure for all-day radiative cooling10.1038/s41893-019-0348-5 ↗