journal article·2015-05

Optical inspection of solar cells using phase-sensitive optical coherence tomography

Meng-Tsan Tsai, Feng-Yu Chang, Yung-Chi Yao, Jie Mei, Ya-Ju Lee

Publisher page

Abstract

Abstract The inspection and measurement of solar cells has become an important technique in evaluating the efficiency and quality of solar cell devices. Currently, surface defect detection of solar cells can be achieved by several approaches such as machine vision, photoluminescence, and electroluminescence imaging techniques. Nevertheless, it is still difficult to inspect the inner structures of solar cells. In response to this need, scanning electron microscopy (SEM) and transmission electron microscopy (TEM) have become common techniques for investigating the nanostructures of solar cells. However, both carry the disadvantages of destructive imaging, high cost, and a small inspection area. Moreover, it is difficult to simultaneously estimate multiple optical properties with the aforementioned techniques. In this study, we propose the use of phase-sensitive optical coherence tomography (PS-OCT) for the inspection of solar cells. We develop a two-reference-arm configuration to reduce the phase noise that intrinsically accompanies the OCT system. Based on the proposed approach to extract the amplitude and phase terms from OCT interference signals, the 3D microstructure of solar cells can be obtained while simultaneously probing the nanostructures on arbitrary planes of the solar cell. The OCT microstructural results show that the structures of different layers can be nondestructively visualized and quantitatively evaluated. From the phase signal, the inverted pyramid structure, which is commonly used for the reduction of interface reflection, can be visualized. Moreover, based on the two-reference-arm configuration, the optical reflection coefficient (ORC) can be estimated in order to evaluate the interface reflection from the surface of solar cell. Results show that PS-OCT can be a valuable tool for providing nondestructive inspection of the micro/nanostructures of solar cells.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Optical Coherence Tomography Applications · Integrated Circuits and Semiconductor Failure Analysis · Near-Field Optical Microscopy

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. Bifacial dye-sensitized solar cells based on an ionic liquid electrolyte10.1038/nphoton.2008.224 ↗
2. 40% efficient metamorphic GaInP/GaInAs/Ge multijunction solar cells10.1063/1.2734507 ↗
3. Efficient light trapping in inverted nanopyramid thin crystalline silicon membranes for solar cell applications10.1021/nl2045777 ↗
4. Machine-vision-based identification for wafer tracking in solar cell manufacturing10.1016/j.rcim.2013.01.009 ↗
5. Quality control of as-cut multicrystalline silicon wafers using photoluminescence imaging for solar cell production10.1016/j.solmat.2010.06.003 ↗
6. In-line measurement of trench structures caused by the texturization of mc-silicon solar cells10.1016/j.solmat.2011.06.030 ↗
7. Defect detection of solar cells in electroluminescence images using Fourier image reconstruction10.1016/j.solmat.2011.12.007 ↗
8. Defect detection in solar modules using ICA basis images10.1109/TII.2012.2209663 ↗
9. Distinguishing morphological and electrical defects in polycrystalline silicon solar cells using scanning electron acoustic microscopy and electron beam induced current10.1016/j.solmat.2011.05.022 ↗
10. The impact of piezoelectric polarization and nonradiative recombination on the performance of (0001) face GaN/InGaN photovoltaic devices10.1063/1.3301262 ↗
11. Analysis of Cu(In,Ga)(S,Se)(2) thin-film solar cells by means of electron microscopy10.1016/j.solmat.2010.11.008 ↗
12. With Three-dimensional structure of P3HT assemblies in organic solvents revealed by Cryo-TEM10.1021/nl5001967 ↗
13. Optical coherence tomography10.1126/science.1957169 ↗
14. Real-time in vivo computed optical interferometric tomography10.1038/nphoton.2013.71 ↗
15. Spectral domain optical coherence tomography of multi-MHz A-scan rates at 1310 nm range and real-time 4D-display up to 41 volumes/second, Biomed10.1364/BOE.3.003067 ↗
16. Simultaneous 0.8, 1.0, and 1.3 μm multi-spectral and common-path broadband source for optical coherence tomography10.1364/OL.39.000865 ↗
17. High definition live 3D-OCT in vivo: design and evaluation of a 4D OCT engine with 1 GVoxel/s, Biomed10.1364/BOE.5.002963 ↗
18. Defect detection and property evaluation of indium tin oxide conducting glass using optical coherence tomography10.1364/OE.19.007559 ↗
19. Application of optical coherence tomography (OCT) as a 3-dimensional imaging technique for roll-to-roll coated polymer solar cells10.1016/j.solmat.2011.10.004 ↗
20. Online monitoring of printed electronics by spectral-domain optical coherence tomography
21. Phase-resolved optical frequency domain imaging10.1364/OPEX.13.005483 ↗
22. Spectral-domain optical coherence phase microscopy for quantitative phase-contrast imaging10.1364/OL.30.002131 ↗
23. Spectral-domain phase microscopy10.1364/OL.30.001162 ↗
24. Quantitative phase imaging with swept-source optical coherence tomography for optical measurement of nanostructures10.1109/LPT.2012.2184748 ↗
25. Nano-sensitive optical coherence tomography10.1039/C3NR06132A ↗
26. High-dynamic-range quantitative phase imaging with spectral domain phase microscopy10.1364/OL.34.003442 ↗