Three-year weathering tests on asphalt shingles: Solar reflectance

Paul Berdahl, Hashem Akbari, Ronnen Levinson, Jeffry Jacobs, Frank Klink, Rebecca Everman

Publisher page

Abstract

Exposed asphalt shingles undergo chemical and physical changes as they weather. Here we focus on the resulting changes in solar reflectance. Most roofing granules employing inorganic metal oxide pigments are very stable. Initial reflectance changes are therefore due to changes in the asphalt itself, and the loss of processing oils coating the granules. Ultraviolet-induced photo-oxidation of these oils and exposed asphalt produces dark hydrophilic substances that are removed by rain, or in dry climates, transported by dew. After six months, changes in solar reflectance are small and (in California) mainly due an annual cycle of accumulation of atmospheric dust and its removal by rain. In hot humid climates cyanobacteria grow rapidly on granule surfaces, creating dark stains that reduce reflectance by as much as 0.06 at 3 years. We show that in these types of climates (exemplified by Houston) biocide additives such as Cu2O can be employed to maintain solar reflectance. When cyanobacteria are absent, solar reflectance changes over the first three years are on the order of 0.02 or less, and may be either positive or negative.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Building materials and conservation · Biocrusts and Microbial Ecology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (12)

Show source-provided references
1. Potential benefits of cool roofs on commercial buildings: conserving energy, saving money, and reducing emission of greenhouse gases and air pollutants10.1007/s12053-008-9038-2 ↗
2. Cool communities: strategies for heat island mitigation and smog reduction10.1016/S0378-7788(97)00063-7 ↗
3. Global cooling: increasing world-wide urban albedos to offset CO210.1007/s10584-008-9515-9 ↗
4. Radiative forcing and temperature response to changes in urban albedos and associated CO2 offsets10.1088/1748-9326/5/1/014005 ↗
5. CRRC-1 Standard pub. by Cool Roof Rating Council, Oakland, CA. Available at 〈www.coolroofs.org〉 (2010).
6. M. Sleiman, G. Ban-Weiss, H.E. Gilbert, D. Franc-ois, P. Berdahl, T.W. Kirch- stetter, H. Destaillats, R. Levinson, Soiling of building envelope surfaces and its effect on solar reflectance—part I: analysis of roofing product databases, Solar Energy Materials and Solar Cells, 95 3385–3399, in press (Fig. 4(d) and (e)).10.1016/j.solmat.2011.08.002 ↗
7. Aluminum pigments – radiant energy reflection, barrier protection, and improved film durability
8. Asphalt Roofing Manufacturers Association (ARMA), Water soluble residue found on asphalt roofing products (“tobacco-juicing”), Technical Bulletin (November, 2006). See 〈www.asphaltroofing.org/pdf/tb_tobacco_juicing.pdf〉.
9. Weathering of roofing materials – an overview10.1016/j.conbuildmat.2006.10.015 ↗
10. Understanding the long-term effects of environmental exposure on roof reflectance in California10.1016/j.conbuildmat.2011.06.052 ↗
11. Surface roughness effects on the solar reflectance of cool asphalt shingles10.1016/j.solmat.2007.10.011 ↗
12. Biodiversity of cyanobacteria and green algae on monuments in the Mediterranean Basin: an overview10.1099/mic.0.032508-0 ↗