journal article·2014-05Open access

A method for estimating cell temperature at the maximum power point of a HCPV module under actual operating conditions

Eduardo F. Fernández, P. Rodrigo, F. Almonacid, P. Pérez-Higueras

Abstract

The operating cell temperature of a HCPV module or system is a key factor, because it directly affects efficiency and reliability. Hence, the accurate estimation of cell temperature in a HCPV module is crucial. Under real operating conditions, HCPV modules work at the maximum power point, because they are connected to an inverter. At the maximum power point, the cell temperature is lower than the cell temperature of open circuit, because solar cells are generating power which is not transformed into heat. At present, none of the existing methods are valid to estimate the operating cell temperature of a HCPV module connected to an inverter. In this paper, a procedure for estimating this temperature is introduced. The results show that the proposed method performs effectively in the estimation of the cell temperature in a HCPV module connected to an inverter. In addition, an analysis of the difference between the cell temperature of open circuit and the cell temperature at the maximum power point in a HCPV is conducted and a difference of up to 21 °C has been found.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: solar cell performance optimization · Thin-Film Transistor Technologies · Photovoltaic System Optimization Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Solar cell generations over 40% efficiency10.1002/pip.1255 ↗
2. Concentrated solar energy applications using Fresnel Lenses: a review
3. High concentration photovoltaic systems applying III–V cells10.1016/j.rser.2009.07.002 ↗
4. Luque · 2011
5. High concentrator photovoltaics efficiencies: present status and forecast10.1016/j.rser.2010.11.046 ↗
6. Photovoltaic concentration at the onset of its commercial deployment10.1002/pip.705 ↗
7. Multi-junction III–V solar cells: current status and future potential10.1016/j.solener.2004.09.018 ↗
9. Energy production of photovoltaic systems: fixed, tracking, and concentrating10.1016/j.rser.2011.07.156 ↗
10. Modeling of a concentrating photovoltaic system for optimum land use10.1002/pip.1176 ↗
11. Analysis of temperature coefficients for III–V multi-junction concentrator cells
12. Temperature coefficients of monolithic III–V triple-junction solar cells under different spectra and irradiance levels10.1063/1.4753865 ↗
13. E.F. Fernández, A.J.G. Loureiro, P.J.P. Higueras, G. Siefer, Monolithic III–V triple-junction solar cells under different temperatures and spectra, Proceedings of the 8th Spanish Conference on Electron Devices, CDE, 2011, Art. no. 5744222.10.1109/SCED.2011.5744222 ↗
14. Investigations on the temperature dependence of CPV modules equipped with triple-junction solar cells10.1002/pip.987 ↗
15. E. Fernández, P. Pérez-Higueras, F. Almonacid, A. García-Loureiro, J. Fernández, P. Rodrigo, P. Vidal and G. Almonacid, Quantifying the effect of air temperature in CPV modules under outdoor conditions, AIP Conf. Proc., 1477, 2012, p. 194–197.10.1063/1.4753866 ↗
16. Cooling of photovoltaic cells under concentrated illumination: a critical review10.1016/j.solmat.2004.09.003 ↗
17. Models for the electrical characterization of high concentration photovoltaic cells and modules: a review10.1016/j.rser.2013.06.019 ↗
18. M.D. Yandt, J.F. Wheeldon, J. Cook, R. Beal, A.W. Walker, O. Thériault, H. Sehriemer, T.J. Hall, K. Hinzer, Estimating cell temperature in a concentrating photovoltaic system, AIP Conference Proceedings, 1477, 2012, pp. 172–175.10.1063/1.4753861 ↗
19. IEC 60904-5:2011. Photovoltaic devices - Part 5: Determination of the equivalent cell temperature (ECT) of photovoltaic (PV) devices by the open-circuit voltage method.
20. Determining outdoor CPV cell temperature10.1063/1.3658355 ↗
21. An improved temperature estimation method for solar cells operating at high concentrations10.1016/j.solener.2013.02.028 ↗
22. E.F. Fernandez, A.J.G. Loureiro, P. Rodrigo, F. Almonacid, J.I. Fernandez, P.J.P. Higueras, G. Almonacid, Calculation of cell temperature in a HCPV module using Voc, Proceedings of the 2013 Spanish Conference on Electron Devices, CDE, 2013, Art. no. 6481406, pp. 317–320.
23. A method for using CPV modules as temperature sensors and its application to rating procedures10.1016/j.solmat.2011.03.030 ↗
24. King · 2004
25. F. Rubio, M. Martinez, R. Coronado, J.L. Pachon, P. Banda, Deploying CPV power plants - ISFOC experiences, Conference Record of the IEEE Photovoltaic Specialists Conference, 2008, Art. no. 4922733.10.1109/PVSC.2008.4922733 ↗
26. Y. Ota, H. Nagai, K. Araki and K. Nishioka, Temperature distribution in 820X CPV module during outdoor operation, AIP Conf. Proc., 1477, 2012, 364–367.10.1063/1.4753906 ↗
27. Calculation of the cell temperature of a High Concentration Photovoltaic (HCPV) module: a study and comparison of different methods10.1016/j.solmat.2013.11.009 ↗
28. Y. Ota, H. Nagai, K. Araki and K. Nishioka, Thermal transfer simulation for concentrator photovoltaic receiver under concentration, AIP Conf. Proc., 1556, 2013, 18–21.10.1063/1.4822189 ↗
29. A two subcell equivalent solar cell model for III–V triple junction solar cells under spectrum and temperature variations10.1016/j.solener.2013.03.012 ↗
30. Concentrator multifunction solar cell characteristics under variable intensity and temperature10.1002/pip.834 ↗
31. Multijunction solar cell model for translating I–V characteristics as a function of irradiance, spectrum, and cell temperature10.1002/pip.965 ↗
32. M. Liu, G.S. Kinsey, W. Bagiensky, A. Nayak and V. Garboushian, Measurement of mismatch loss in CPV modules, AIP Conf. Proc. 1477, 2012, 165–167.10.1063/1.4753859 ↗
33. Relation between the cell temperature of a HCPV module and atmospheric parameters10.1016/j.solmat.2012.06.043 ↗
34. Outdoor evaluation of concentrator photovoltaic systems modules from different manufacturers: first results and steps10.1002/pip.1262 ↗