Quantitative depth profile analysis of boron implanted silicon by pulsed radiofrequency glow discharge time-of-flight mass spectrometry
Source abstract
Abstract
Abstract The analytical potential of pulsed radiofrequency glow discharge time-of-flight mass spectrometry (pulsed-rf-GD-TOFMS) is investigated for fast quantitative analysis of major and dopant elements in bulk and thin film layers. This technique does not require sampling at ultra-high vacuum conditions and so it facilitates high sample throughput compared to reference techniques as secondary ionization mass spectrometry (SIMS). In this paper, bulk and boron implanted silicon samples are analyzed. Boron concentration in Si samples is calculated from calibration curves obtained using solar grade silicon and B doped silicon wafers as calibrating materials, and using 29Si+ ion signal as internal standard. Qualitative depth profiles of 10B implanted silicon are determined in a few seconds using the low-pressure pulsed-rf-GD-TOFMS system. Additionally, quantitative depth profiles are easily determined making use of the calibration curves. A good agreement with the depth profiles measured using SIMS was obtained, demonstrating the analytical potential of the pulsed-GD-TOFMS system for fast, sensitive and high depth resolution analysis of implanted silicon samples.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Ion-surface interactions and analysis · Mass Spectrometry Techniques and Applications · Integrated Circuits and Semiconductor Failure Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (15)
Show source-provided references
1. Critical revision of GD-MS, LA-ICP-MS and SIMS as inorganic mass spectrometric techniques for direct solid analysis10.1039/b904698d ↗
2. Vickerman · 1998
3. Laser ablation inductively coupled plasma mass spectrometry for direct analysis of the spatial distribution of trace elements in metallurgical-grade silicon10.1007/s00216-006-0658-0 ↗
4. Glow-discharge spectrometry for direct analysis of thin and ultra-thin solid films10.1016/j.trac.2005.04.019 ↗
5. Development and characterization of a Grimm-type glow discharge ion source operated with high gas flow rates and coupled to a mass spectrometer with high mass resolution10.1016/S0584-8547(02)00106-4 ↗
6. Quantitative measurement of boron and phosphorous in solar grade silicon feedstocks by high resolution fast-flow glow discharge mass spectrometry
7. Glow discharge spectroscopy for depth profile analysis: from micrometer to sub-nanometer layers10.1007/s00216-005-0143-1 ↗
8. Direct chemical in-depth profile analysis and thickness quantification of nanometer multilayers using pulsed-rf-GD-TOFMS10.1007/s00216-009-3382-8 ↗
9. A comparison of non-pulsed radiofrequency and pulsed radiofrequency glow discharge orthogonal time-of-flight mass spectrometry for analytical purposes10.1039/b908038d ↗
10. Pulsed r.f.-glow-discharge time-of-flight mass spectrometry for fast surface and interface analysis of conductive and non-conductive materials10.1002/sia.2253 ↗
11. Pulsed radiofrequency glow discharge time of flight mass spectrometer for the direct analysis of bulk and thin coated glasses10.1039/b804169p ↗
12. The concept of plasma cleaning in glow discharge spectrometry10.1039/b818343k ↗
13. Explicit chemical speciation by microsecond pulsed glow discharge time-of-flight mass spectrometry: concurrent acquisition of structural, molecular and elemental information10.1039/a905477d ↗
14. A. Tempez, N. Bordel, M. Hohl, A. Menendez, L. Lobo, J. Orphal, C. Diplasu, A. Surmeian, M. Ganciu, T. Nakamura, Ionization processes in a Grimm type source used in pulsed r.f.-glow-discharge time-of- flight mass spectrometry, in: Proceedings of the 18th International Symposium on Plasma Chemistry, Kyoto, Japan, August 26–31 (2007).
15. A. Menéndez, PhD Thesis, Descargas Luminiscentes Acopladas a Espectrometría Óptica y de Masas en el Análisis de Semiconductores, Óxidos y Nitruros, University of Oviedo, 2006.