journal article·2026-07Open access

Machine Learning‐Driven Capillary Microfluidic Design Automation for Programmable Gradient Generation and Antimicrobial Testing

Mahmood Khalghollah, Azam Zare, Sorosh Abdollahi, Behrouz H. Far, Amir Sanati Nezhad

Small· Volume 22· Issue 37

Abstract

ABSTRACT Rapid, portable, and automated determination of minimum inhibitory concentration (MIC) is critical for antimicrobial susceptibility testing in decentralized settings. We present TCG‐CMDA (Tree‐Shaped Concentration Gradient generator enabled by Capillary Microfluidic Design Automation), a machine learning–guided platform for the automated design of capillary microfluidic chips that passively generate programmable concentration gradients. A key innovation of TCG‐CMDA is its ability to achieve fully synchronized, capillary‐driven flow of two preloaded agents, enabling precise and reproducible gradient formation without external pumps or valves. By integrating computational fluid dynamics (CFD) simulations, a neural network surrogate model, and quasi‐Newton optimization, the platform customizes tree‐shaped geometries to match target mixing profiles. We validate TCG‐CMDA through dye flow visualization and MIC testing of Escherichia coli against gentamicin, showing high concordance with conventional antibiotic susceptibility testing. The resulting chip supports a streamlined workflow consisting of passive loading, autonomous gradient generation, and incubation (∼2 h), followed by direct endpoint assessment, making it well suited for decentralized point‐of‐care applications. TCG‐CMDA establishes a closed‐loop, simulation‐guided design paradigm for capillary microfluidic systems. Although demonstrated here for MIC‐oriented antimicrobial testing, the framework is generalizable and can be extended to other gradient‐dependent microfluidic applications through geometry reconfiguration and fluid‐specific optimization.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Microfluidic and Capillary Electrophoresis Applications · Microfluidic and Bio-sensing Technologies · Innovative Microfluidic and Catalytic Techniques Innovation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Electrical and Software Engineering University of Calgary Calgary Alberta Canada

BioMEMS and Bioinspired Microfluidic Laboratory Department of Mechanical and Manufacturing Engineering University of Calgary Calgary Alberta Canada

Department of Biomedical Engineering Schulich School of Engineering University of Calgary Calgary Alberta Canada

Department of Mechanical and Manufacturing Engineering University of Calgary Calgary Alberta Canada

Funding

Natural Sciences and Engineering Research Council of Canada

References (51)

Show source-provided references
1. O'Neill J. · 2016 · 88
2. 10.1038/nprot.2007.52110.1038/nprot.2007.521 ↗
3. Evaluation of an Automated Rapid Phenotypic Antimicrobial Susceptibility Testing (ASTar, Q‐linea AB) Applied Directly on Blood Cultures Bottles Positive for Gram‐negative Pathogens
4. 10.3390/antibiotics1002020910.3390/antibiotics10020209 ↗
5. 10.1038/s41579‐020‐0327‐x10.1038/s41579‐020‐0327‐x ↗
6. POCT Accreditation ISO 15189 and ISO 22870: Making the Point
7. 10.1039/D3LC00796K10.1039/D3LC00796K ↗
8. 10.3390/diagnostics1008050910.3390/diagnostics10080509 ↗
9. 10.1039/D1LC00879J10.1039/D1LC00879J ↗
10. 10.1021/ac026144910.1021/ac0261449 ↗
11. 10.1038/s41378‐022‐00360‐810.1038/s41378‐022‐00360‐8 ↗
12. 10.1039/D4LC00706A10.1039/D4LC00706A ↗
13. 10.1038/s41586‐022‐04683‐410.1038/s41586‐022‐04683‐4 ↗
14. 10.1002/adma.20200871210.1002/adma.202008712 ↗
15. 10.1039/D2LC00878E10.1039/D2LC00878E ↗
16. 10.1038/s41586-019-1635-z10.1038/s41586-019-1635-z ↗
17. 10.1016/j.ces.2004.11.03310.1016/j.ces.2004.11.033 ↗
18. 10.1088/0960‐1317/25/9/09400110.1088/0960‐1317/25/9/094001 ↗
19. The Growth of Capillary Networks by Branching for Maximum Fluid Access
20. 10.3390/ijms1205326310.3390/ijms12053263 ↗
21. 10.3390/mi809027410.3390/mi8090274 ↗
22. 10.1088/0960‐1317/15/2/R0110.1088/0960‐1317/15/2/R01 ↗
23. 10.1039/D0RA00263A10.1039/D0RA00263A ↗
24. 10.1063/5.021936810.1063/5.0219368 ↗
25. 10.1039/b305892a10.1039/b305892a ↗
26. 10.1021/la000600b10.1021/la000600b ↗
27. 10.1007/s11859-018-1317-y10.1007/s11859-018-1317-y ↗
28. 10.1063/1.512120010.1063/1.5121200 ↗
29. 10.3390/chemosensors1101000210.3390/chemosensors11010002 ↗
30. 10.3390/bios1410050710.3390/bios14100507 ↗
31. 10.1039/b821021g10.1039/b821021g ↗
32. 10.1039/c2lc20800h10.1039/c2lc20800h ↗
33. 10.1038/s41378‐020‐00200‐710.1038/s41378‐020‐00200‐7 ↗
34. 10.4172/2161‐1009.100032010.4172/2161‐1009.1000320 ↗
35. 10.1109/ACCESS.2022.315832710.1109/ACCESS.2022.3158327 ↗
36. 10.1039/B813582G10.1039/B813582G ↗
37. 10.1016/j.ijheatmasstransfer.2022.12311010.1016/j.ijheatmasstransfer.2022.123110 ↗
38. 10.3390/mi1507090110.3390/mi15070901 ↗
39. 10.1016/j.ijheatmasstransfer.2023.12451910.1016/j.ijheatmasstransfer.2023.124519 ↗
40. 10.1038/s41467‐020‐20284‐z10.1038/s41467‐020‐20284‐z ↗
41. 10.1038/s41598‐025‐11508‐710.1038/s41598‐025‐11508‐7 ↗
42. 10.3390/mi401000110.3390/mi4010001 ↗
43. 10.1007/s00604‐022‐05316‐310.1007/s00604‐022‐05316‐3 ↗
44. 10.1039/C2LC41083D10.1039/C2LC41083D ↗
45. 10.1002/apj.240710.1002/apj.2407 ↗
46. 10.1016/j.ces.2012.03.03610.1016/j.ces.2012.03.036 ↗
47. 10.1126/science.106623810.1126/science.1066238 ↗
48. 10.1016/j.cej.2009.02.03310.1016/j.cej.2009.02.033 ↗
49. 10.1039/C5LC00836K10.1039/C5LC00836K ↗
50. 10.3390/mi1205053310.3390/mi12050533 ↗
51. 10.3390/mi1209111310.3390/mi12091113 ↗