The effect of the strengthening of AAC masonry walls using FRCM system
Source abstract
Abstract
This paper describes results from testing the tensile strength of compressed masonry walls strengthened with fiber-reinforced cement matrix [FRCM] system on one side, both sides, or without any strengthening. Test models were prepared from masonry units made of autoclaved aerated concrete SOLBET OPTIMAL 4/600. Walls were built with a ready-mixed mortar for thin layer joints of class M5, without fi lling head joints. PBO fi bre grids embedded in a mineral matrix were used as superfi cial strengthening. Lateral surfaces of masonry walls were strengthened with ready-mixed mortar PBO-MX GOLD MASONRY with embedded grid PBO--MESH GOLD 22/22. Then, the surface layer of ready-mix mortar PBO-MX GOLD MASONRY was applied. The used superfi cial strengthening provided an additional strengthening of the cracked models and their safer behaviour after failure.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Innovative concrete reinforcement materials · Concrete and Cement Materials Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Silesian University of Technology, Department of Building Structures
BUDINŻ PB sp. z o.o.
References
Reference metadata was not supplied for this record.